Reduction of contrast medium volume in abdominal aorta CTA: Multiphasic injection technique versus a test bolus volume

Author:

Nijhof Wouter H.,van der Vos Charlotte S.,Anninga Bauke,Jager Gerrit J.,Rutten Matthieu J.C.M.

Publisher

Elsevier BV

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Reference23 articles.

1. Dose reduction with adaptive bolus chasing computed tomography angiography;Cai;The Journal of X-ray Science and Technology,2010

2. Effects of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography;Bae;Radiology,2007

3. Contrast enhancement in cardiovascular MDCT: effect of body weight, height, body surface area, body mass index, and obesity;Bae;American Journal of Roentgenology,2008

4. Contrast-induced nephropathy;Walsh;Journal of Endovascular Therapy,2007

5. Contrast-induced nephropathy;Gleeson;American Journal of Roentgenology,2004

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3