Reduction of Carry over in Liquid-Handling Systems with a Decontamination Step Integrated in the Washing Procedure

Author:

Iten Miriam1,Weibel Roland1,König Iwo1,Beckbissinger Rainer2,Benthien Thomas3,Hälg Werner4,Ingenhoven Nikolaus4,Lehnert Angela5,Oeltjen Lars2,Zaborosch Christiane

Affiliation:

1. Zurich University of Applied Science, Institute of Chemistry and Biological Chemistry, Wädenswil, Switzerland

2. Hamilton Bonaduz AG, Bonaduz, Switzerland

3. Surface Contacts GmbH, Saarbrücken, Germany

4. Tecan Schweiz AG, Männedorf, Switzerland

5. Sias AG, Hombrechtikon, Switzerland

Abstract

Robotic liquid-handling systems can be equipped with disposable pipetting tips or fixed reusable pipetting tips. The use of disposable tips is perceived as the best option to avoid carry over (CO) of analyte from sample to sample. We recently developed standardized CO test procedures that allow precise and reproducible quantification of CO for fixed reusable tips. We used these test procedures to reduce CO of the analytes fluorescein, IgG, and hepatitis B surface antigen (HBsAg) to minimal levels. Variations of washing intensity, using water as a washing solution, did not lower CO below acceptable target levels. These target levels would preclude a false-positive detection of IgG and HBsAg in human serum when a negative sample is measured subsequent to a sample with a high analyte concentration. We therefore integrated a decontamination step into the washing procedure. Screening of 12 decontamination solutions showed that sodium hypochlorite solution was very efficient in reducing CO. Optimization led to a final washing routine in which tips are exposed for 0.2 s to 0.17 M NaOCI and subsequently rinsed with 2 mL of water to remove any remaining decontaminant solution. The washing procedure only takes 15 s and is thus suitable for high-throughput applications. The procedure was able to lower CO of IgG and HBsAg in human sera below relevant levels. The decontamination step with hypochlorite can easily be integrated into different liquid-handling systems and is likely to be effective against CO of most proteins and peptides.

Publisher

SAGE Publications

Subject

Medical Laboratory Technology,Computer Science Applications

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3