Soil texture and salinity effects on calibration of TDR300 dielectric moisture sensor

Author:

Kargas George,Ntoulas Nikolaos,Nektarios Panayiotis A.

Abstract

Newly developed sensors have simplified real-time determination of soil water content (θm). Although the TDR300 is one of the most recent dielectric sensors, little is known with regard to the accuracy and dependency of its measurements of soil type and other environmental factors. In this study, the performance of TDR300 was investigated using liquids of known dielectric properties and a set of porous media with textures ranging from sandy to clayey. The experiments were conducted in the laboratory by mixing different amounts of water with each soil to obtain a sufficient range of soil water contents. For sand, the calculated permittivity values (εr) correlated adequately with Topp’s equation derived for time domain reflectometry. However, for the remaining inorganic porous media, εr values were overestimated compared with those resulting from Topp’s equation, especially for water contents exceeding 0.2 cm3/cm3. The results suggested that the relationship between θm and √εr was strongly linear (0.953< r2 <0.998). The most accurate results were provided by soil-specific calibration equations, which were obtained by the multi-point calibration equation. However, two-point calibration equations determined water content in all tested soils reasonably well, except for clay soil. A linear regression equation was developed that correlated the slope of the relationship θm–√εr with bulk soil electrical conductivity (EC). The regression slope was influenced more by soil EC than by soil texture. Also, TDR300 response was investigated in bi-layered systems (liquid–air and saturated porous media–air). In a bi-layered sensing volume characterised by strongly contrasting dielectric values, the appropriate bulk permittivity values for water and loam soil were determined by arithmetic rather than refractive index averaging, while for butanol and sand these values remained somewhere between the two averaging schemes, indicating that the upward infiltration calibration technique is inappropriate for the TDR300 sensor. Soil solute EC, as determined by measurements conducted in liquids and sand, significantly affected permittivity values at much lower levels than the limit of EC <2 dS/m, as suggested by the manufacturer. However, the relationship θm–√εr remained linear up to EC 2 dS/m, which corresponded to a bulk soil EC value of 0.6 dS/m. By contrast, for EC values >2 dS/m, the relationship θm–√εr was not linear, and, thus the TDR300 device calibration became increasingly difficult. Therefore, rather than operating as a time domain device, TDR300 operates as a water content reflectometer type device.

Publisher

CSIRO Publishing

Subject

Earth-Surface Processes,Soil Science,Environmental Science (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3