Potential of Far-Ultraviolet Absorption Spectroscopy as a Highly Sensitive Analysis Method for Aqueous Solutions. Part II: Monitoring the Quality of Semiconductor Wafer Cleaning Solutions Using Attenuated Total Reflection

Author:

Higashi Noboru1,Ikehata Akifumi1,Kariyama Naomi1,Ozaki Yukihiro1

Affiliation:

1. Kurabo Industries Ltd., 14-5 Shimokida-cho, Neyagawa 572-0823, Japan (N.H., N.K.); and Department of Chemistry, School of Science and Technology, Kwansei Gakuin University, 2-1 Gakuen, Sanda 669-1337, Japan (A. I., Y.O.)

Abstract

Far-ultraviolet (FUV) spectroscopy combined with attenuated total reflection (ATR) is employed for direct measurement of the concentrations of semiconductor wafer cleaning fluids such as SC-1 (aqueous solution of NH3 and H2O2) and SC-2 (aqueous solution of HCl and H2O2). FUV spectra of these aqueous solutions in the 170–200 nm region are highly sensitive to changes in both hydrogen bonding and hydration. Although ATR measurement results in lower absorptivity compared to transmittance measurement, it is possible to increase absorption with greater evanescent wave penetration depth using a low refractive index internal reflection element (IRE). We adopt quartz as an IRE material. Since the refractive index of quartz becomes lower than that of water in the low energy side of an intense absorption band due to the n → σ* transition of water, the quartz IRE yields non-total reflection wavelength regions. However, near 175 nm the effective absorptivity of the tail of water's absorption band can be successfully enlarged, making the FUV-ATR technique suitable for measuring the concentrations of the components in the semiconductor wafer cleaning fluids. In the present study we prepared the same cleaning fluids as those used in actual semiconductor fabrication and measured their FUV-ATR spectra in the 150–300 nm wavelength range. It was found that even with the quartz IRE one can measure FUV-ATR spectra under total reflection conditions at 175 nm or above. We created calibration models for predicting both NH3 and H2O2 in the concentration ranges of 0–10% in SC-1 using multiple linear regression (MLR). The standard deviations of the models were 0.033% and 0.265% for NH3 and H2O2, respectively. The same procedure was repeated under the same conditions for HCl and H2O2 in SC-2, yielding corresponding values of 0.018% for HCl and 0.178% for H2O2.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3