Characterization of the Interaction between 4-(Tetrahydro-2-Furanmethoxy)-N-Octadecyl-1,8-Naphthalimide and Human Serum Albumin by Molecular Spectroscopy and Its Analytical Application

Author:

Sun Yang1,Wei Song1,Zhao Yingyong1,Hu Xiaoyun1,Fan Jun1

Affiliation:

1. School of Chemical Engineering, Northwest University, No.229 Taibai North Road, Xi'an, Shaanxi 710069, China (Y.S., S.W., J.F.); Biomedicine Key Laboratory of Shaanxi Province, Northwest University, No.229 Taibai North Road, Xi'an, Shaanxi 710069, China (Y.Z.); and Department of Physics, Northwest University, No.229 Taibai North Road, Xi'an, Shaanxi 710069, China (X.H.)

Abstract

A novel 4-(tetrahydro-2-furanmethoxy)- N-octadecyl-1,8-naphthalimide (TNN) was synthesized as a spectrofluorimetric probe for the determination of proteins. The effect of different solvents on the spectral characteristics of TNN was investigated. The results showed that TNN displayed dependent solvent polarity properties due to the effect of internal charge transfer. The interactions between TNN and human serum albumin (HSA) were studied by fluorescence and absorption spectroscopy. Fluorescence data revealed that the fluorescence quenching of HSA by TNN was the result of the formation of TNN–HSA complex. The binding parameters of interactions between TNN and HSA at different temperatures were obtained according to the Stern–Volmer equation. The thermodynamic parameters, enthalpy change (ΔH) and entropy change (ΔS), for the interactions were calculated to be −7.31 kJ mol−1 and 72.75 J mol−1 K−1 according to the van't Hoff equation, indicating that the hydrogen bonds and hydrophobic interactions were the dominant intermolecular force in stabilizing the complex. The effect of TNN on the conformation of HSA was analyzed by circular dichroism and synchronous fluorescence spectroscopy. Furthermore, the results of displacement experiments using warfarin indicated that TNN could bind to site I of HSA. The fluorescence of TNN could be largely quenched by HSA, based on which a new fluorometric method for detecting HSA in the HCl-Tris buffer solution (pH = 7.4) was developed. The linear ranges of the calibration curves were 0.1~14.2 μM for HSA, 0.1~13.0 μM for bovine serum albumin (BSA), 0.2~9.7 μM for γ-globulin, and 0.3~11.3 μM for hemoglobin (Hb), with detection limits (3σ) of 13.7 × 10−10 M for HSA, 1.84 × 10−10 M for BSA, 3.14 × 10−10 M for γ-globulin, and 6.86 × 10−10 M for Hb. The effect of metal cations on the fluorescence spectra of TNN in ethanol was also investigated. The method has been applied to the determination of total proteins in human serum samples collected from the hospital and the results were in good agreement with those reported by the hospital.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3