Affiliation:
1. IBM Technology Laboratory, 1701 North Street (T43), Endicott, New York 13760
Abstract
The frequency-quadrupled output of a Nd:YAG laser (266 nm) is focused to a spot of about 10 micrometers diameter and used to ablate eight industrially important polymers of known composition within a Fourier transform ion cyclotron resonance mass spectrometer (FTICR). The spectra usually show distinct and dramatic differences compared with those obtained with conventional laser microprobes based on a time-of-flight approach. Although rearrangement products are more prevalent than structural ions, the spectra are directly distinguishable by qualitative inspection. Spectra are consistent with two simple mechanisms for formation of rearrangement products: carbon clustering and condensation of stable subunits. High-mass C clusters resembling the “fullerenes,” including a particularly prominent C60 peak, are observed for poly(phenylene sulfide). Other polymers show low- and intermediate-mass C cluster distributions in positive-ion spectra. Odd-mass ion series which are consistent with the formula HA mB n+, where A and B are molecular fragments or atoms, are observed. Negative-ion spectra generally show more structural information than corresponding positive-ion spectra.
Subject
Spectroscopy,Instrumentation
Cited by
26 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献