Author:
Faridah F,Utami Sentagi,Yanti Ressy,Sunarno S,Nurjani Emilya,Wijaya Rony
Abstract
This paper discusses an analysis to obtain the optimal thermal sensor placement based on indoor thermal characteristics. The method relies on the Computational Fluid Dynamics (CFD) simulation by manipulating the outdoor climate and indoor air conditioning (AC) system. First, the alternative sensor's position is considered the optimum installation and the occupant's safety. Utilizing the Standardized Euclidean Distance (SED) analysis, these positions are then selected for the best position using the distribution of the thermal parameters' values data at the activity zones. Onsite measurement validated the CFD model results with the maximum root means square error, RMSE, between both data sets as 0.8°C for temperature, the relative humidity of 3.5%, and an air velocity of 0.08m/s, due to the significant effect of the building location. The Standardized Euclidean Distance (SED) analysis results are the optimum sensor positions that accurately, consistently, and have the optimum % coverage representing the thermal condition at 1,1m floor level. At the optimal positions, actual sensors are installed and proven to be valid results since sensors could detect thermal variables at the height of 1.1m with SED validation values of 2.5±0.3, 2.2±0.6, 2.0±1.1, for R15, R33, and R40, respectively.
Publisher
Centre for Evaluation in Education and Science (CEON/CEES)
Subject
Mechanical Engineering,General Engineering,Safety, Risk, Reliability and Quality,Transportation,Renewable Energy, Sustainability and the Environment,Civil and Structural Engineering
Reference27 articles.
1. H. Batih and C. Sorapipatana. (2016). Characteristics of urban households' electrical energy consumption in Indonesia and its saving potentials. Renew. Sustain. Energy Rev., vol. 57, pp. 1160-1173, DOI: 0.1016/j. rser.2015.12.132;
2. ASHRAE Standard 55. (2010). Thermal environmental conditions for human occupancy. American Society of Heating Refrigerating and Air-Conditioning Engineers, Inc, Atlanta;
3. P. Fanger. (1970). Thermal comfort: Analysis and Applications in Environmental Engineering. Danish Technical Press, Copenhagen, Denmark;
4. K. Parsons. (2003). Human Thermal Environments: The Effects of Hot, Moderate, and Cold Environments on Human Health, Comfort and Performance, Second Edition. Taylor & Francis Group, Boca Raton;
5. M. J. Varas-Muriel, R. Fort, M. I. Martínez-Garrido, A. Zornoza-Indart, and P. López-Arce. (2014). Fluctuations in the indoor environment in Spanish rural churches and their effects on heritage conservation: Hygro-thermal and CO2 conditions monitoring. Build. Environ., vol. 82, pp. 97-109, DOI: 10.1016/j.buildenv.2014.08.010;