Temperature measurement in combustion flow field with femtosecond laser-induced filament

Author:

Li Shuai-Yao,Zhang Da-Yuan,Gao Qiang,Li Bo,He Yong,Wang Zhi-Hua, ,

Abstract

Laser-based diagnostic techniques are critical nonintrusive methods of measuring the in-situ temperature in combustion flow fields. Developing temperature measurement techniques with high accuracy and precision is of great significance for studying the combustion. At present, nanosecond (ns) lasers are commonly used in these methods. However, the researches based on femtosecond (fs) lasers are relatively few. Here, we develop a thermometry technique for combustion fields based on fs laser-induced filament. When the fs laser propagates in an optical medium, a long uniformly distributed plasma channel (also named filament) will be generated. The clamped intensity inside the filament is high enough to generate excited atoms/molecules through fs laser-induced photochemical reactions. Subsequently, the excited atoms/molecules release fluorescence signals. The length of the filament can be measured by imaging the fluorescence signal with an ICCD camera, which is evaluated by the full width at half maximum (FWHM) of the spatial distribution of the filament emission signal. Based on theoretical analysis, the experimental data of the filament length are fitted with a power function, and the result is satisfactory compared with the <i>R</i>-squared measure of goodness (<i>R</i><sup>2</sup>) of 0.984. This indicates that the filament length is correlated well with the temperature of the combustion field. A monotonic quantitative relationship between the filament length and the temperature can be established by a calibration process, and then the temperature of the combustion field can be measured. When the temperature changes from 1630 to 2007 K, the length of the filament shortens by 38%. This indicates that the filament length is sensitive to the temperature of the flow field. When the temperature is 2007 K, the absolute uncertainty of the measurement is ±25 K, and the relative uncertainly is about 1.2%. The spatial resolution of the measurement system is 50 μm, which was determined by a USAF 1951 Target. Based on the spatial resolution, the measurement precision can arrive at 17 K. Although, at present, this temperature measurement technique based on femtosecond laser-induced filament is used only in laminar premixed flames, it has potential applications in temperature measurements ranging from room temperature to combustion temperatures.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3