Measurement of ultrashort laser pulses with rapid-scanning frequency-resolved optical gating device

Author:

Wen Jin-Hui,Hu Ting,Wu Qin-Fei,

Abstract

Frequency-resolved optical gating (FROG) is now one of the main methods of characterizing the ultrashort laser pulses. There are mainly three SHG-FROG methods, i.e. the standard FROG, the single-shot FROG and GRENOUILLE, each of which has its own features and application areas. Although the standard SHG-FROG has balanced advantages in sensitivity, accuracy and applicability for various test pulses, its speed is much slower than the others’: it often takes a few seconds or even minutes to record the FROG trace, which is dependent on the size of FROG image. Nowadays continuous development of the technique of digital imaging brings to high resolution CCD/CMOS image cameras with tens of millions pixels and fast refreshing rate. Unfortunately the standard FROG cannot make use of these image cameras for the real-time measurement of ultrashort pulses. To solve this problem, in this paper a rapid-scanning FROG device based on the standard SHG-FROG is demonstrated, where sinusoidal waves from a signal generator synchronously drive a voice coil actuator and a galvo-scanner, so that the spectra of the autocorrelation at different delays are successively reflected onto an area camera. As long as the camera is triggered to shoot continuously, the entire FROG trace can be recorded quickly within 1 s. Furthermore, several guidelines for good performance with this device are provided, including the settings of the amplitude and frequency of the driving sinusoidal waves, the selections of the focuses of the collimating lens F<sub>1</sub> and the focusing lens F<sub>2</sub>, and the method of delay calibration. This device is suitable for the real-time measurement of ultrashort pulses with large chirps or complex structures where large-size FROG images need to be captured. In order to show the capability of this device, femtosecond pulses delivered directly from a home-made Kerr-lens mode-locked Ti: sapphire laser as well as the chirp pulses dispersed by a 200 mm-thick BK7 slab are measured. Two scan ranges are selected in order to achieve enough effective data points in the FROG traces of these two test pulses. Using standard procedure of pulse retrieval of FROG, the two pulses are reconstructed with pulse widths 58 fs and 492 fs, respectively. From the retrieved spectral phases of these test pulses, the GDD value of the BK7 slab can be deduced to be 8740 fs<sup>2</sup>, which is in good agreement with the theoretical value of 8815 fs<sup>2</sup>. Thus the experimental results confirm the accuracy and applicability of this FROG device.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3