Investigation into the design and diffraction efficiency of shifted dual transmission grating

Author:

Yi Tao ,Wang Chuan-Ke ,Yang Jin-Wen ,Zhu Xiao-Li ,Xie Chang-Qing ,Liu Shen-Ye , , , ,

Abstract

In inertial confined fusion (ICF) experiments, the temporal evolution of X-ray spectrum can provide important diagnostic information such as electron temperature and density on laser-plasma interaction. Accurate diagnostic requires a wide range of X-ray spectrum from several hundred eV to kilo eV to be measured with high temporal resolution. For traditional single grating spectrometer coupled with streak cameras, the limited recording length of streak cameras severely restricts measured X-ray spectral range in one laser shot. Here we design a shifted dual transmission grating (SDTG) spectrometer for laser-produced plasma X-ray diagnostics in ICF experiments which can provide wide-range X-ray spectrum measurement from 100 eV to 5 keV with high temporal and spectral resolution. This SDTG spectrometer comprises two X-ray gratings: one with high line density and the other with low line density. The high line density grating is used to measure X-ray spectrum from 1000 eV to 5000 eV and the low line density grating measures X-ray spectrum from 100 eV to 1000 eV respectively. These two kinds of X-ray gratings are arranged in a plane with their centers shifted by a certain distance. A shifted double slit component is designed according to the spatial positions of the two gratings and set in front of the photocathode in the streak camera to ensure that two sets of X-ray spectra by two shifted gratings are projected on the photocathode without overlapping. This novel SDTG-based X-ray spectrometer can take the most of recording panel space, offering a path to realize a high resolution and broad spectral ranges in diagnosing soft X-rays. In this paper, the design method and the technical data of the SDTG-based X-ray spectrometer are given. The SDTG-based X-ray spectrometer is integrated, debugged and used to measure X-ray pulse at SG-III prototype facility located in Laser Fusion Research Center of Chinese Academy of Engineering Physics. The time integral results are captured by the SDTG spectrometer in the ICF fluid RT experiments and time-resolved spectra are recorded in indirect drive implosion experiment. Experimental results show the SDTG-based X-ray spectrometer can capture X-ray spectrum ranging from 0.1 keV to 5 keV, with a spectral resolution of 0.04 nm and a temporal resolution of better than 30 ps. By fully utilizing limited recording length, the SDTG-based X-ray spectrometer can realize a wide range temporal X-ray spectrum measurement with enough spectral resolution and temporal resolution. This SDTG spectrometer is a good temporal X-ray diagnostic tool for ICF experiments and other high energy density physics experiments.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3