X-ray source with quasi-monochromatic parallel beam

Author:

Wang Rui-Rong ,An Hong-Hai ,Xiong Jun ,Xie Zhi-Yong ,Wang Wei ,

Abstract

In inertial confined fusion experiments, an excellent-performance and high-efficiency X-ray source plays an important role in X-ray radiography schemes. Indeed, it can be used in a variety of X-ray experimental techniques. The mono-chromaticity, flux intensity, degree of collimation (the radiation can be transported long distances without loss), and spot size of the X-ray source affect the quality of imaging. Ray-tracing simulations, which are validated by experimental results, demonstrate that high-intensity collimated X-ray beams can be produced from an isotropic X-ray source. Therefore, a method of improving the performance of an X-ray source from a laser-produced plasma is presented. A spherically bent crystal is used to collimate mono-chromatic X-rays emitted from a laser-produced plasma. Here we design a spherically bent crystal spectrometer system for collimating the laser-produced X-rays. The system performance is experimentally tested at the Shenguang Ⅱ (SGⅡ) laser facility located in Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences. The beam divergence is measured by using a metal grid placed downstream from the crystal, the metal grid that possesses wires with 60 μm in diameter and 127 μm in period. An imaging plate (IP) is placed at various distances downstream from grid. The quality of the generated beam is monitored by measuring the dimensions of the grid image formed by the beam on IP. While the narrow range of wavelength is measured with a spherically bent crystal spectrometer. Experimental results show that the spherically bent crystal spectrometer system can produce quasi-monochromatic (10<sup>-3</sup> < △ <i>λ/λ</i> <10<sup>-2</sup>) X-ray beams with a high degree of collimation (less than 2 mrad divergence), uniform spot size (~500 μm), and a relative tenability in the wide spectral range. The influences of various experimental parameters on the quality of beam collimation are evaluated in two ways. They can be investigated in test experiments by representing the beam divergence distribution as a function of Bragg angle. In another study of the effect of the aberrations, when the incident beam on the spherically bent crystal is not normal, the beam is less collimated in the tangential plane, and out of collimation in the sagittal plane. Following the ray-tracing method, we analyze the diffracted beam divergence produced by the astigmatic aberration. The qualitative conclusion is that the good agreement with the experimental results is obtained. By fully utilizing limited Bragg angle range, the spherically bent crystal spectrometer system can realize collimated diffracted X-ray beams with divergence of less than 1 mrad by using a laser-produced plasma X-ray source under the appropriately experimental parameters.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3