Measurement of microwave electric field based on electromagnetically induced transparency by using cold Rydberg atoms

Author:

Zhou Fei,Jia Feng-Dong,Liu Xiu-Bin,Zhang Jian,Xie Feng,Zhong Zhi-Ping, , ,

Abstract

Microwave electric fields are measured by using cold Rydberg atoms. We obtain spindle-shaped cold atomic clouds in a magneto-optical trap and then pump the cold atoms to quantum state 5S<sub>1/2</sub>, <i>F</i> = 2, <i>m</i><sub>F</sub> = 2 by using an optical-pump laser. We obtain the Rydberg electromagnetic induction transparency (EIT) spectrum peak with narrow linewidth by the low temperature and small residual Doppler broadening. The results show that the typical EIT linewidth with 16 μK cold atoms is about 460 kHz which is 15 times narrower than that of 7 MHz obtained in the thermal vapor cell. The microwave electric field amplitude is measured by Autler-Townes splitting (EIT-AT splitting) in the cold atoms at frequencies of 9.2, 14.2 and 22.1 GHz, receptively. The results show that there is a good linear relationship between the EIT-AT splitting interval and the microwave electric field amplitude. The lower limit of the microwave electric field amplitude that can be measured in the linear region can reach as low as 222 μV/cm, which is about 22 times larger than the lower limit in the traditional thermal vapor cell about of 5 mV/cm. The improvement of the lower limit by EIT-AT splitting method is roughly proportional to the narrowing EIT line width by cold atom samples. This demonstrates that benefiting from the smaller residual Doppler effect and the narrower EIT linewidth in cold atoms, the cold atom system is more advantageous in the experimental measuring of the weak microwave electric field amplitude by using the EIT-AT splitting method. This is of great benefit to the absolute calibration of very weak microwave electric fields. Furthermore, the lower limit of the microwave electric field amplitude that can be measured is smaller than 1 μV/cm by using the change of transmittance of the prober laser at the EIT resonance, and the corresponding sensitivity can reach 1 μV·cm<sup>–1</sup>·Hz<sup>–1/2</sup>. These results demonstrate the advantages of cold atomic sample in microwave electric field measurement and its absolute calibration.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Improving the spectral resolution and measurement range of quantum microwave electrometry by cold Rydberg atoms;Journal of Physics B: Atomic, Molecular and Optical Physics;2023-01-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3