Calibration of the dynamic spatial resolution of framing image-converter

Author:

Yuan Zheng ,Dong Jian-Jun ,Li Jin ,Chen Tao ,Zhang Wen-Hai ,Cao Zhu-Rong ,Yang Zhi-Wen ,Wang Jing ,Zhao Yang ,Liu Shen-Ye ,Yang Jia-Min ,Jiang Shao-En ,

Abstract

In order to improve the two-dimensional imaging diagnostic accuracy of inertial confinement fusion (ICF) experiment, a calibration method of the dynamic spatial resolution of X-ray framing image-converter (XFIC) is proposed. When an object with straight edge function is projected onto the photocathode of XFIC as an input, edge spread function can be obtained by recording an image of the XFIC output. The first derivative of the edge spread function produces the line spread function (LSF). Then the modulation transfer function (MTF) of the system can be worked out by Fourier transform of the LSF. Therefore, the spatial resolution can be deduced. According to this theory, the spatial resolution of XFIC can be obtained. Based on SG-Ⅱ laser facility, the calibrating X-ray source is generated by 8 bundled lasers bombarding the target. High-Z knife-edge is irradiated by the X-ray and imaged on the photocathode of XFIC, and then a dynamic image is obtained as the system works in the gating mode. By handling the dynamic image, the LSF of XFIC is given by analyzing the edge image. Then the MTF of the camera can be indicated by the Fourier transform of the LSF. When the MTF is 0.1, the corresponding spatial resolution of the imaging system is 20 lp/mm. According to the dynamic spatial resolution theory of framing image-converter, the extreme spatial resolution is 22.8 lp/mm. The calibration result agrees with the theoretical results. By contrast, the static spatial resolution of the same X-ray framing image-converter calibrated by the traditional method is presented here. The calibrated static spatial resolution is 22 lp/mm, a little higher than the dynamic one. During the two-dimensional imaging diagnosis, the X-ray framing image-converter works in the dynamic gating mode, thus the calibrated dynamic spatial resolution can be more truthful to reflect its imaging diagnosis ability.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3