In situ tuning hydrostatic pressure at low temperature using electrically driven diamond anvil cell

Author:

Ding Kun ,Wu Xue-Fei ,Dou Xiu-Ming ,Sun Bao-Quan ,

Abstract

Traditionally, a diamond anvil cell (DAC) operated at low temperature can be pressurized by using a helium-driven piston or remote control tightening mechanism. This approach of pressurizing DAC is not convenient for operating at low temperature. Here we develop a low-temperature pressurizing technique for in situ tuning pressure in DAC at 20 K by an electrically driven method. The improved DAC pressure apparatus is composed of traditional DAC device and a piezoelectric actuator (PZT). Here the PZT used in the experiment is the PSt 150/1010/40 supplied by the Piezomechanik. Both parts are assembled together in a red copper or stainless steel cylinder. The DAC part is thermally contacted with a low temperature holder for cooling the chamber of the DAC in the experiment. The wires of the PZT connect with the voltage source through the wiring terminals of the cryostat. As the DAC apparatus cools down, two electrodes of the PZT are connected together when a voltage difference between the electrodes is generated. When the temperature of the DAC chamber arrives at the presetting value, two electrodes of the PZT are connected with the voltage source for applying voltage to the PZT. In this paper, we find that the PZT stroke shows a linear increase with increasing voltage at 300 K, whereas it is approximately linear at 80 and 6 K. The maximum strokes are 40, 26 and 15 upm at 300, 80 and 6 K respectively when the applied voltage is 120 V. The experimental results show that the PZT-driven DAC apparatus can continuously generate pressure from 0.49 to 4.41 GPa at low temperature and applied voltage of 0-290 V, where at zero voltage an initial pressure of 0.49 GPa is generated by using driven screws of the DAC device at room temperature. The pressure in the DAC chamber is determined by the red shift of ruby florescence line. The calibrated chamber temperature in DAC is determined as a function of pressure (PZT voltage) by using the intensity ration (R2/R1) of ruby R2 and R1 fluorescence lines. We find that the chamber temperature only slightly increases with increasing pressure in a range of (19 1) K. The main difference between the present device and the other tuning DAC apparatus is that the force on the DAC can be conveniently applied by using PZT voltage. This guarantees a high pressure-tuned resolution in the experiment, e. g., we tune a single InAs quantum dot (QD) emission wavelength to match the cavity mode. Such a tuning technique is found to have applications in realizing a compact tunable single photon source or completing two-photon interference of Hong-Ou-Mandel experiments between the QD and nitrogen vacancy center in diamond or atom, respectively.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3