Abstract

Context: Calculating the resistance provided by elastic resistance is essential with the aim of adjusting the load and controlling the progression of the exercises in programs using elastic resistance. This study aimed (1) to establish a model of the force elongation for CLX bands; (2) to examine whether these models are altered by different aspects of band elongation: the phase of elongation and shortening (concentric and eccentric phases), the elongation speed, and the initial resting length; and (3) to determine the resistance value for 100% of elongation in each color and to compare it with the values reported by Theraband. Design: Cross‐sectional. Methods: Ten CLX bands of each color were elongated by 2 experienced researchers to establish their elongation force curves in series of 10 repetitions per band using a Smith machine for an anchor, examining whether elongation force models were affected by elongation and shortening phases using one 4-loop CLX band stretched to 100% and at 0.50 m/s, elongation speed stretching two 4-loop CLX bands at 0.50 m/s and at 0.70 m/s, and different starting lengths using 3 CLX bands (2, 3, and 4 loops) stretched at 0.50 m/s. Results: No differences were found in the comparisons between phases, speeds, or different start lengths (mean errors ranged from 0.01 [0.07 N] for the blue band to 2.97 [0.94 N] for the gold band). Our values were higher than the reference values provided by Theraband for all colors, ranging from 2.3% to 33.1%. Conclusions: Our findings show that the values provided by the brand underestimate the resistance provided by CLX bands. To solve this, regression equations are provided so professionals can calculate the resistance of CLX bands based on their elongation. In addition, these models are not influenced by the phase of elongation and shortening, the elongation speed, and the initial resting length.

Publisher

Human Kinetics

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Tissue Flossing: A Commentary on Clinical Practice Recommendations;International Journal of Sports Physical Therapy;2024-04-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3