Affiliation:
1. 1University of Florida
Abstract
The authors tested 4 young healthy subjects walking with a powered knee exoskeleton to determine if it could reduce the metabolic cost of locomotion. Subjects walked with a backpack loaded and unloaded, on a treadmill with inclinations of 0° and 15°, and outdoors with varied natural terrain. Participants walked at a self-selected speed (average 1.0 m/s) for all conditions, except incline treadmill walking (average 0.5 m/s). The authors hypothesized that the knee exoskeleton would reduce the metabolic cost of walking uphill and with a load compared with walking without the exoskeleton. The knee exoskeleton reduced metabolic cost by 4.2% in the 15° incline with the backpack load. All other conditions had an increase in metabolic cost when using the knee exoskeleton compared with not using the exoskeleton. There was more variation in metabolic cost over the outdoor walking course with the knee exoskeleton than without it. Our findings indicate that powered assistance at the knee is more likely to decrease the metabolic cost of walking in uphill conditions and during loaded walking rather than in level conditions without a backpack load. Differences in positive mechanical work demand at the knee for varying conditions may explain the differences in metabolic benefit from the exoskeleton.
Subject
Rehabilitation,Orthopedics and Sports Medicine,Biophysics
Cited by
55 articles.