Is the Concept, Method, or Measurement to Blame for Testing Error? An Illustration Using the Force-Velocity-Power Profile

Author:

Samozino Pierre1,Rivière Jean Romain1,Jimenez-Reyes Pedro2,Cross Matt R.3,Morin Jean-Benoît34

Affiliation:

1. Univ Savoie Mont Blanc, Interuniversity Laboratory of Human Movement Sciences, EA 7424, Chambéry, France

2. Center for Sport Studies, Rey Juan Carlos University, Madrid, Spain

3. Sports Performance Research Institute New Zealand (SPRINZ), Auckland University of Technology, Auckland, New Zealand

4. UJM-Saint-Etienne, Université de Lyon, Interuniversity Laboratory of Human Movement Sciences, EA 7424, Saint-Etienne, France

Abstract

When poor reliability of “output” variables is reported, it can be difficult to discern whether blame lies with the measurement (ie, the inputs) or the overarching concept. This commentary addresses this issue, using the force-velocity-power (FvP) profile in jumping to illustrate the interplay between concept, method, and measurement reliability. While FvP testing has risen in popularity and accessibility, some studies have challenged the reliability and subsequent utility of the concept itself without clearly considering the potential for imprecise procedures to impact reliability measures. To this end, simulations based on virtual athletes confirmed that push-off distance and jump-height variability should be <4% to 5% to guarantee well-fitted force–velocity relationships and acceptable typical error (<10%) in FvP outputs, which was in line with previous experimental findings. Thus, while arguably acceptable in isolation, the 5% to 10% variability in push-off distance or jump height reported in the critiquing studies suggests that their methods were not reliable enough (lack of familiarization, inaccurate procedures, or submaximal efforts) to infer underpinning force-production capacities. Instead of challenging only the concept of FvP relationship testing, an alternative conclusion should have considered the context in which the results were observed: If procedures’ and/or tasks’ execution is too variable, FvP outputs will be unreliable. As for some other neuromuscular or physiological testing, the FvP relationship, which magnifies measurement errors, is unreliable when the input measurements or testing procedures are inaccurate independently from the method or concept used. Field “simple” methods require the same methodological rigor as “lab” methods to obtain reliable output data.

Publisher

Human Kinetics

Subject

Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3