Reproducibility of the Rotor 2INpower Crankset for Monitoring Cycling Power Output: A Comprehensive Analysis in Different Real-Context Situations

Author:

Rodríguez-Rielves Víctor,Martínez-Cava Alejandro,Buendía-Romero Ángel,Lillo-Beviá José Ramón,Courel-Ibáñez Javier,Hernández-Belmonte Alejandro,Pallarés Jesús G.

Abstract

Purpose: To examine the reproducibility (intradevice and interdevice agreement) of the Rotor 2INpower device under a wide range of cycling conditions. Methods: Twelve highly trained male cyclists and triathletes completed 5 cycling tests, including graded exercise tests at different cadences (70–100 rpm), workloads (100–650 W), pedaling positions (seated and standing), and vibration conditions (20–40 Hz) and an 8-second maximal sprint (>1000 W). An intradevice analysis included a comparison between the power output registered by 3 units of Rotor 2INpower, whereas the power output provided by each one of these units and the gold-standard SRM crankset were compared for the interdevice analysis. Among others, statistical calculations included the standard error of measurement, expressed in absolute (in watts) and relative terms as the coefficient of variation (CV). Results: Except for the graded exercise test seated at 100 rpm/100 W (CV = 10.2%), the intradevice analysis showed an acceptable magnitude of error (CV ≤ 6.9%, standard error of measurement ≤ 12.3 W) between the 3 Rotor 2INpower. Similarly, these 3 units showed an acceptable agreement with the gold standard in all graded exercise test situations (CV ≤ 4.0%, standard error of measurement ≤ 13.1 W). On the other hand, both the intradevice and interdevice agreements proved to be slightly reduced under high cadences (intradevice: CV ≤ 10.2%; interdevice: CV ≤ 4.0%) and vibration (intradevice: CV ≤ 4.0%; interdevice: CV ≤ 3.6%), as well as during standing pedaling (intradevice: CV ≤ 4.1%; interdevice: CV ≤ 2.5%). Although within the limits of an acceptable agreement, measurement errors increased during the sprint tests (CV ≤ 7.4%). Conclusions: Based on these results, the Rotor 2INpower could be considered a reproducible tool to monitor power output in most cycling situations.

Publisher

Human Kinetics

Subject

Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3