Bessone Andrea,Carassale Luigi,Guida Roberto,Kubín Zdeněk,Lo Balbo Antonio Alfio,Brunenghi Michela Marrè,Pinelli Lorenzo
Abstract
As LP steam turbines are requested to work at strong part-loads, LSB stalled and unstalled flutter may occur. Testing on a downscaled steam turbine in T10MW test plant have been carried out to measure LSB aggregated damping at low load. Also numerical analysis to predict aerodynamic damping have been performed and results have been compared to experimental data, allowing software tool validation at low load.
Publisher
Czech Technical University in Prague - Central Library
Cited by
3 articles.
订阅此论文施引文献