Interfacial shear rheology of glassy polymers at liquid interfaces

Author:

Alexandris Stelios12ORCID,Ashkenazi Daniel3,Vermant Jan4ORCID,Vlassopoulos Dimitris12ORCID,Gottlieb Moshe3ORCID

Affiliation:

1. Institute of Electronic Structure and Laser, FORTH 1 , Heraklion 71110, Crete, Greece

2. Department of Materials Science and Technology, University of Crete 2 , Heraklion 71003, Crete, Greece

3. Department of Chemical Engineering, Ben Gurion University 3 of the Negev, Beer Sheva 8410501, Israel

4. Department of Materials, ETH Zurich 4 CH-8093, Zurich, Switzerland

Abstract

When surface-active molecules or particles assemble at fluid–fluid interfaces, these interfaces acquire complex rheological properties that are of importance in processes that involve flow and deformation of interfaces. Although much progress has been made, interfacial rheology measurements and, in particular, the measurement of interfacial rheological properties of polymers at the air-water interface remain challenging. These are due to weak interactions with the water subphase, the polymer backbone conformation, the glass transition of the interfacial layer, and memory effects. In the present work, we describe systematic rheological measurements of polymer-laden interfaces. The measurements were performed with four different interfacial shear rheometers that can be classified into two types: rheometers in which the surface pressure can be controlled independently, and devices based on fixtures mounted on standard rotational rheometers and lacking control of the surface pressure. We use poly(tert-butyl methacrylate) and poly(methyl methacrylate), two high glass transition temperature, hydrophobic polymers anchored to the water subphase by means of the acrylate group. Using a Langmuir–Pockels (LP) trough, we identify the transition of the polymer monolayer from a viscous to a solid elastic or soft-glassy interface as the polymer surface concentration increases by compression. Then, we compare the linear viscoelastic properties of the interface as obtained by each rheometer. Our results show poor reproducibility and comparability of the rheological data as obtained by different rheometers for the same polymer. This is mainly due to differences in the method used to prepare the layers. For LP-based devices, spreading under dilute conditions and subsequent compression yields layers of compressed glassy blobs with reproducible results. On the other hand, for devices without surface pressure control, deposition of the amount needed to reach a desired concentration may lead to the formation of ill-defined layers resulting in irreproducible data. Furthermore, we find that only when spreading the polymer to form a dilute layer and then controlling the surface pressure by compression, we can clearly distinguish the fluidlike from solidlike interfaces, and a clear correlation is observed between the surface pressure (or interfacial polymer concentration) and the rheological properties of the interface.

Funder

Horizon 2020 Framework Programme

Publisher

Society of Rheology

Subject

Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science

Reference47 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3