Tissue Oximetry as a Potential Alternative to Indocyanine Green (ICG) Perfusion Assessment in Colorectal Anastomotic Cases

Author:

Gonzalez-Jacobo Alexander1ORCID,Chandler Paul1,Martz Joseph2,Sherwinter Danny1

Affiliation:

1. Department of Advanced Minimally Invasive Surgery, Maimonides Medical Center, Brooklyn

2. Department of Surgery, Northwell Health, New Hyde Park, NY

Abstract

Introduction: Anastomotic margin tissue perfusion is recognized as critical to successful colorectal anastomosis creation. Near-infrared (NIR) fluorescence imaging with indocyanine green (ICG) is the most common modality used by surgeons as an adjunct to clinical assessment in confirming the adequacy of tissue perfusion. Tissue oxygenation as a surrogate for tissue perfusion has been described in a variety of surgical specialties but its use in colorectal surgery has been limited. Here, we report our experience using a handheld tissue-oxygen meter, IntraOx, for the evaluation of colorectal tissue bed oxygen saturation (StO2) and compared its utility with NIR-ICG in identifying the viability of colonic tissue before anastomosis in a range of colorectal procedures. Materials and Methods: This was an institutional review board–approved multicenter trial consisting of 100 patients undergoing elective colon resections. After specimen mobilization, a clinical margin was chosen based on the oncologic, anatomic, and clinical assessment as per the clinicians’ standard technique. The IntraOx device was then used to take a baseline reading of colonic tissue oxygenation on a normal segment of perfused colon. Following this, measurements were taken circumferentially at 5 cm intervals along the bowel proximally and distally to the clinical margin. A StO2 margin was then determined based on the point at which the StO2 dropped off by ≥10 percentage points. This was then compared with the NIR-ICG margin using the Spy-Phi system. Results: StO2 was found to have a sensitivity and specificity of 94.8% and 93.1%, respectively, and a positive predictive value and negative predictive value of 93.5% and 94.5%, respectively when compared with NIR-ICG. At the 4-week follow-up, no significant complications or leaks were reported. Conclusions: The IntraOx handheld device was found to be similar to NIR-ICG in identifying a well-perfused margin of colonic tissue while having the added benefits of high portability and reduced costs. Further studies looking at the effect of the IntraOx on preventing colonic anastomotic complications such as leak and stricture are warranted.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3