The Safe Values of Quantitative Perfusion Parameters of ICG Angiography Based on Tissue Oxygenation of Hyperspectral Imaging for Laparoscopic Colorectal Surgery: A Prospective Observational Study

Author:

Son Gyung Mo12ORCID,Nazir Armann M.3ORCID,Yun Mi Sook2,Lee In Young2,Im Sun Bin4ORCID,Kwak Jae Yeong5,Park Sang-Ho5ORCID,Baek Kwang-Ryul5ORCID,Gockel Ines6ORCID

Affiliation:

1. Department of Surgery, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan 50612, Republic of Korea

2. Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan 50612, Republic of Korea

3. School of Medicine, Royal College of Surgeons in Ireland, University of Medicine and Health Sciences, D02 YN77 Dublin, Ireland

4. Department of Medicine, Pusan National University School of Medicine, Yangsan 50612, Republic of Korea

5. Department of Electronics Engineering, Pusan National University, Busan 46241, Republic of Korea

6. Department of Visceral, Transplantation, Thoracic and Vascular Surgery, University Hospital Leipzig, 04103 Leipzig, Germany

Abstract

Background: Safe values for quantitative perfusion parameters of indocyanine green (ICG) angiography have not been fully defined, and interpretation remains at the surgeon’s discretion. This prospective observational study aimed to establish the safe values for the quantitative perfusion parameters by comparing tissue oxygenation levels from HSI images in laparoscopic colorectal surgery. Methods: ICG angiography was performed using a laparoscopic near-infrared (NIR) camera system with ICG diluted in 10 mL of distilled water. For quantitative perfusion parameters, the changes in fluorescence intensity with perfusion times were analyzed to plot a time–fluorescence intensity graph. To assess real-time tissue oxygen saturation (StO2) in the colon, the TIVITA® Tissue System was utilized for hyperspectral imaging (HSI) acquisition. The StO2 levels were compared with the quantitative perfusion parameters derived from ICG angiography at corresponding points to define the safe range of ICG parameters reflecting good tissue oxygenation. Results: In the regression analysis, T1/2MAX, TMAX, slope, and NIR perfusion index were correlated with tissue oxygen saturation. Using this regression model, the cutoff values of quantitative perfusion parameters were calculated as T1/2MAX ≤ 10 s, TMAX ≤ 30 s, slope ≥ 5, and NIR perfusion index ≥50, which best reflected colon StO2 higher than 60%. Diagnostic values were analyzed to predict colon StO2 of 60% or more, and the ICG perfusion parameters T1/2MAX, TMAX, and perfusion TR showed high sensitivity values of 97% or more, indicating their ability to correctly identify cases with acceptable StO2. Conclusion: The safe values for quantitative perfusion parameters derived from ICG angiography were T1/2MAX ≤ 10 s and TMAX ≤ 30 s, which were associated with colon tissue oxygenation levels higher than 60% in the laparoscopic colorectal surgery.

Funder

Pusan National University Yangsan Hospital

Publisher

MDPI AG

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Using Hyper Spectral Imaging to Optimize Treatment Protocols in Sustainable Medical Settings;2024 International Conference on Optimization Computing and Wireless Communication (ICOCWC);2024-01-29

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3