Using the Entropy of Tracheal Sounds to Detect Apnea during Sedation in Healthy Nonobese Volunteers

Author:

Yu Lu1,Ting Chien-Kun2,Hill Bryce E.3,Orr Joseph A.4,Brewer Lara M.5,Johnson Ken B.4,Egan Talmage D.6,Westenskow Dwayne R.6

Affiliation:

1. Lecturer, Department of Biomedical Engineering, College of Basic Medical Sciences, China Medical University, Shenyang, Liaoning, P. R. China.

2. Assistant Professor, Department of Anesthesiology, Taipei Veterans General Hospital and National Yang-Ming University, Taipei, Taiwan.

3. Assistant Professor, Department of Electrical Engineering, Montana Tech, Butte, Montana.

4. Associate Professor, Department of Anesthesiology, University of Utah, Salt Lake City, Utah.

5. Assistant Professor, Department of Anesthesiology, University of Utah.

6. Professor, Department of Anesthesiology, University of Utah.

Abstract

AbstractBackground:Undetected apnea can lead to severe hypoxia, bradycardia, and cardiac arrest. Tracheal sounds entropy has been proved to be a robust method for estimating respiratory flow, thus maybe a more reliable way to detect obstructive and central apnea during sedation.Methods:A secondary analysis of a previous pharmacodynamics study was conducted. Twenty volunteers received propofol and remifentinal until they became unresponsive to the insertion of a bougie into the esophagus. Respiratory flow rate and tracheal sounds were recorded using a pneumotachometer and a microphone. The logarithm of the tracheal sound Shannon entropy (Log-E) was calculated to estimate flow rate. An adaptive Log-E threshold was used to distinguish between the presence of normal breath and apnea. Apnea detected from tracheal sounds was compared to the apnea detected from respiratory flow rate.Results:The volunteers stopped breathing for 15 s or longer (apnea) 322 times during the 12.9-h study. Apnea was correctly detected 310 times from both the tracheal sounds and the respiratory flow. Periods of apnea were not detected by the tracheal sounds 12 times. The absence of tracheal sounds was falsely detected as apnea 89 times. Normal breathing was detected correctly 1,196 times. The acoustic method detected obstructive and central apnea in sedated volunteers with 95% sensitivity and 92% specificity.Conclusions:We found that the entropy of the acoustic signal from a microphone placed over the trachea may reliably provide an early warning of the onset of obstructive and central apnea in volunteers under sedation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3