Supplemental Oxygen Compromises the Use of Pulse Oximetry for Detection of Apnea and Hypoventilation During Sedation in Simulated Pediatric Patients

Author:

Keidan Ilan12,Gravenstein Dietrich2,Berkenstadt Haim13,Ziv Amitai3,Shavit Itay4,Sidi Avner12

Affiliation:

1. Department of Anesthesia and Intensive Care

2. Department of Anesthesiology, University of Florida College of Medicine, Gainesville, Florida

3. Israel Center for Medical Simulation, Sheba Medical Center, Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel

4. Department of Pediatric Emergency Medicine, Rambam Medical Center, Haifa, Israel

Abstract

OBJECTIVE. The goal was to assess the time to recognition of apnea in a simulated pediatric sedation scenario, with and without supplemental oxygen. METHODS. A pediatric human patient simulator mannequin was used to simulate apnea in a 6-year-old patient who received sedation for resetting of a fractured leg. Thirty pediatricians participating in a credentialing course for sedation were randomly assigned to 2 groups. Those in group 1 (N = 15) used supplemental oxygen, and those in group 2 (N = 15) did not use supplemental oxygen. A third group (N = 10), consisting of anesthesiology residents (postgraduate years 2 and 3 equivalent), performed the scenario with oxygen supplementation, to ensure validity and reliability of the simulation. The time interval from simulated apnea to bag-mask ventilation was recorded. Oxygen saturation and Paco2 values were recorded. All recorded variables and measurements were compared between the groups. RESULTS. The time interval for bag-mask ventilation to occur in group 1 (oxygen supplementation) was significantly longer than that in group 2 (without oxygen supplementation) (173 ± 130 and 83 ± 42 seconds, respectively). The time interval for bag-mask ventilation to occur was shorter in group 3 (anesthesiology residents) (24 ± 6 seconds). Paco2 reached a higher level in group 1 (75 ± 26 mmHg), compared with groups 2 and 3 (48 ± 10 and 42 ± 3 mmHg, respectively). There was no significant difference between the groups in oxygen saturation values at the time of clinical detection of apnea (93 ± 5%, 88 ± 5%, and 94 ± 7%, respectively). CONCLUSIONS. Hypoventilation and apnea are detected more quickly when patients undergoing sedation breathe only air. Supplemental oxygen not only does not prevent oxygen desaturation but also delays the recognition of apnea.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

Cited by 59 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3