Accuracy of Postoperative End-tidal Pco2Measurements with Mainstream and Sidestream Capnography in Non-obese Patients and in Obese Patients with and without Obstructive Sleep Apnea

Author:

Kasuya Yusuke1,Akça Ozan2,Sessler Daniel I.3,Ozaki Makoto4,Komatsu Ryu5

Affiliation:

1. Research Fellow, Department of Anesthesiology and Perioperative Medicine, University of Louisville, and Attending physician, Department of Anesthesiology, Tokyo Women's Medical University.

2. Associate Professor, Department of Anesthesiology and Perioperative Medicine, Neuroscience ICU, University of Louisville.

3. Professor and Chair, Department of Outcomes Research, The Cleveland Clinic.

4. Professor and Chair, Department of Anesthesiology, Tokyo Women's Medical University.

5. Research Fellow, Outcomes Research Institute, University of Louisville, and Clinical Instructor, Department of Anesthesiology, Tokyo Women's Medical University.

Abstract

Background Obtaining accurate end-tidal carbon dioxide pressure measurements via nasal cannula poses difficulties in postanesthesia patients who are mouth breathers, including those who are obese and those with obstructive sleep apnea (OSA); a nasal cannula with an oral guide may improve measurement accuracy in these patients. The authors evaluated the accuracy of a mainstream capnometer with an oral guide nasal cannula and a sidestream capnometer with a nasal cannula that did or did not incorporate an oral guide in spontaneously breathing non-obese patients and obese patients with and without OSA during recovery from general anesthesia. Methods The study enrolled 20 non-obese patients (body mass index less than 30 kg/m) without OSA, 20 obese patients (body mass index greater than 35 kg/m) without OSA, and 20 obese patients with OSA. End-tidal carbon dioxide pressure was measured by using three capnometer/cannula combinations (oxygen at 4 l/min): (1) a mainstream capnometer with oral guide nasal cannula, (2) a sidestream capnometer with a nasal cannula that included an oral guide, and (3) a sidestream capnometer with a standard nasal cannula. Arterial carbon dioxide partial pressure was determined simultaneously. The major outcome was the arterial-to-end-tidal partial pressure difference with each combination. Results In non-obese patients, arterial-to-end-tidal pressure difference was 3.0 +/- 2.6 (mean +/- SD) mmHg with the mainstream capnometer, 4.9 +/- 2.3 mmHg with the sidestream capnometer and oral guide cannula, and 7.1 +/- 3.5 mmHg with the sidestream capnometer and a standard cannula (P < 0.05). In obese non-OSA patients, it was 3.9 +/- 2.6 mmHg, 6.4 +/- 3.1 mmHg, and 8.1 +/- 5.0 mmHg, respectively (P < 0.05). In obese OSA patients, it was 4.0 +/- 3.1 mmHg, 6.3 +/- 3.2 mmHg, and 8.3 +/- 4.6 mmHg, respectively (P < 0.05). Conclusions Mainstream capnometry performed best, and an oral guide improved the performance of sidestream capnometry. Accuracy in non-obese and obese patients, with and without OSA, was similar.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference29 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3