Inter-session repeatability of reading performance measures in patients with neovascular AMD

Author:

Boscia Giacomo1,Ricardi Federico1,Gelormini Francesco1,Marica Valentina1,Conte Fabio1,Ghilardi Andrea1,Viggiano Pasquale2,Marolo Paola1,Bandello Francesco34,Borrelli Enrico34ORCID,Reibaldi Michele1

Affiliation:

1. Department of Ophthalmology, University of Turin, Italy

2. Department of Basic Medical Sciences, Neuroscience and Sense Organs, University of Bari “Aldo Moro”, 70121 Bari, Italy

3. Vita-Salute San Raffaele University Milan, Italy

4. IRCCS San Raffaele Scientific Institute, Milan, Italy

Abstract

Purpose: To assess the inter-session repeatability of reading performance measures in patients with previously treated neovascular age-related macular degeneration (AMD) and good best-corrected visual acuity (BCVA) (≥ 20/40 Snellen). Methods: Ninety-one patients (91 eyes) with a diagnosis of previously treated neovascular age-related macular degeneration (AMD) and good BCVA (≥ 20/40 Snellen) were prospectively enrolled. Reading performance metrics were assessed using Radner charts and these measurements were repeated after 7 days in order to obtain the inter-session repeatability. To test repeatability, we calculated the intraclass correlation coefficient (ICC), the 95% coefficient of repeatability (CR) and the coefficient of variation (CV) for each reading parameter: (i) reading acuity (RA - LogRAD); (ii) maximal reading speed (max RS - words per minute); (iii) reading acuity score (RA score - LogRAD); and (iv) critical print size (CPS - LogRAD). Results: Mean±SD BCVA was 0.129±0.0098 LogMAR [range: 0.00-0.30 LogMAR]. The ICC values indicated a good reliability for all the analyzed metrics (0.901 for RA; 0.859 for max RS; 0.906 for RA score; and 0.868 for CPS). The CR was 0.2 LogRAD for RA, 63.2 words per minute for max RS, 0.2 LogRAD for RA score, and 0.2 LogRAD for CPS. CV was 5.5% for RA, 8.9% for max RS, 5.8% for RA score and 6.9% for CPS. Conclusion: Reading performance metrics are characterized by good values of inter-session repeatability in neovascular AMD patients with good BCVA. Our findings may grant the employment of such measures in trials assessing the visual outcome in these patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3