Accuracy and Precision of New Optical Biometer Designed for Myopia Management in Measurement of Ocular Biometry

Author:

Chamarty Sruthi1,Verkicharla Pavan K.

Affiliation:

1. Myopia Research Lab, Prof. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, India

Abstract

SIGNIFICANCE This study provides information about the repeatability of Myopia Master (Oculus, Wetzlar, Germany) and its agreement with Lenstar LS900, which might be useful for the practitioners involved in myopia management. PURPOSE Myopia Master is a new optical biometer that measures ocular biometry and refractive error. The purpose of this study was to assess its repeatability (intrasession and short-term intersession) and its agreement with Lenstar LS900 for the measurement of axial length and corneal curvature. METHODS A total of 304 participants including 254 children (mean ± standard deviation age, 13.7 ± 1.6 years) and 50 adults (24 ± 2.9 years) underwent measurements on Myopia Master and Lenstar LS900 to obtain axial length, flat K, and steep K. On a subset of 30 participants, measurements were obtained with Myopia Master in two sessions that were spread over 10 minutes to assess the short-term intersession repeatability. RESULTS The mean standard deviation of Myopia Master in the measurement of axial length in the total sample was 0.01 mm for intrasession, when the best three measurements were considered. The short-term intersession mean standard deviation for axial length, flat K, and steep K was 0.06 mm, 0.15 D, and 0.21 D, respectively. There were statistically significant differences in mean values of axial length (−0.04 ± 0.06 mm), flat K (−0.07 ± 0.15 D), and steep K (−0.24 ± 0.29 D) between Lenstar LS900 and Myopia Master, with the Lenstar providing slightly longer axial length and steeper K values. Adults showed better repeatability with Myopia Master and better agreement between the biometers for axial length measurement than children. Neither axial length nor refractive error influenced the repeatability or agreement. CONCLUSIONS Myopia Master is repeatable for the measurement of axial length and corneal curvature. Considering the differences in axial length between the Myopia Master and Lenstar LS900, caution must be applied when these biometers are used interchangeably.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Optometry,Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3