Accuracy and Precision of Continuous Noninvasive Arterial Pressure Monitoring Compared with Invasive Arterial Pressure

Author:

Kim Sang-Hyun1,Lilot Marc1,Sidhu Kulraj S.1,Rinehart Joseph1,Yu Zhaoxia1,Canales Cecilia1,Cannesson Maxime1

Affiliation:

1. From the Department of Anesthesiology and Perioperative Care, University of California Irvine, Orange, California (S.-H.K., M.L., K.S.S., J.R., M.C.); Department of Anesthesiology and Pain Medicine, University of Soonchunhyang, Soonchunhyang University Bucheon Hospital, Bucheon, Republic of Korea (S.-H.K., C.C.); Department of Anesthesiology and Critical Care, Louis Pradel Hospital, Lyon, France

Abstract

Abstract Background: Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis. Methods: The authors performed a systematic review and meta-analysis of studies comparing continuous noninvasive arterial pressure monitoring with invasive arterial pressure monitoring. Random-effects pooled bias and SD of bias for systolic arterial pressure, diastolic arterial pressure, and mean arterial pressure were calculated. Continuous noninvasive arterial pressure monitoring was considered acceptable if pooled estimates of bias and SD were not greater than 5 and 8 mmHg, respectively, as recommended by the Association for the Advancement of Medical Instrumentation. Results: Twenty-eight studies (919 patients) were included. The overall random-effect pooled bias and SD were −1.6 ± 12.2 mmHg (95% limits of agreement −25.5 to 22.2 mmHg) for systolic arterial pressure, 5.3 ± 8.3 mmHg (−11.0 to 21.6 mmHg) for diastolic arterial pressure, and 3.2 ± 8.4 mmHg (−13.4 to 19.7 mmHg) for mean arterial pressure. In 14 studies focusing on currently commercially available devices, bias and SD were −1.8 ± 12.4 mmHg (−26.2 to 22.5 mmHg) for systolic arterial pressure, 6.0 ± 8.6 mmHg (−10.9 to 22.9 mmHg) for diastolic arterial pressure, and 3.9 ± 8.7 mmHg (−13.1 to 21.0 mmHg) for mean arterial pressure. Conclusions: The results from this meta-analysis found that inaccuracy and imprecision of continuous noninvasive arterial pressure monitoring devices are larger than what was defined as acceptable. This may have implications for clinical situations where continuous noninvasive arterial pressure is being used for patient care decisions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference64 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3