1. From the Department of Anesthesiology and Pain Management, University of Texas Southwestern and Children’s Medical Center, Dallas, Texas (P.S., J.W.S., P.N.O., R.P.P.); Outcomes Research Consortium, Cleveland, Ohio (P.S., J.W.S., D.I.S., T.E.); Department of Outcomes Research, Cleveland Clinic, Ohio (D.I.S.); and Department of Anesthesia, Edith Wolfson Medical Center, Tel Aviv University, Holon,

Abstract

Abstract Background Pulse oximetry provides no indication of downward trends in Pao2 until saturation begins to decrease. The Oxygen Reserve Index (ORI) is a novel pulse oximeter–based nondimensional index that ranges from 1 to 0 as Pao2 decreases from about 200 to 80 mmHg and is measured by optically detecting changes in Svo2 after Sao2 saturates to the maximum. The authors tested the hypothesis that the ORI provides a clinically important warning of impending desaturation in pediatric patients during induction of anesthesia. Methods After preoxygenation, anesthesia induction, and tracheal intubation, the anesthesia circuit was disconnected and oxygen saturation was allowed to decrease to 90% before ventilation recommenced. The ORI and Spo2 values were recorded from a Masimo Pulse Co-Oximeter Sensor at the beginning of apnea, beginning and end of intubation, beginning and end of the ORI alarm, and 2 min after reoxygenation. Results Data from 25 healthy children, aged 7.6 ± 4.6 yr, were included in the analysis. During apnea, the ORI slowly and progressively decreased over a mean of 5.9 ± 3.1 min from 0.73 ± 0.16 at the beginning of apnea to 0.37 ± 0.11. Spo2 remained 100% throughout this initial period. Concurrently with alarm activation, the ORI began to decrease rapidly, and in median of 31.5 s (interquartile range, 19 to 34.3 s), saturation decreased to 98%. Conclusions In this pilot study, the ORI detected impending desaturation in median of 31.5 s (interquartile range, 19–34.3 s) before noticeable changes in Spo2 occurred. This represents a clinically important warning time, which might give clinicians time for corrective actions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference20 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3