Simulation-based Assessment to Reliably Identify Key Resident Performance Attributes

Author:

Blum Richard H.12,Muret-Wagstaff Sharon L.3,Boulet John R.4,Cooper Jeffrey B.25,Petrusa Emil R.6

Affiliation:

1. Department of Anesthesiology, Perioperative and Pain Medicine, Boston Children’s Hospital and Harvard Medical School, Boston, Massachusetts

2. Center for Medical Simulation, Charlestown, Massachusetts

3. Department of Surgery, Emory University School of Medicine, Atlanta, Georgia

4. Foundation for Advancement of International Medical Education and Research, Philadelphia, Pennsylvania

5. Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts

6. Department of Surgery and Massachusetts General Hospital Learning Laboratory, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts

Abstract

Abstract Background Obtaining reliable and valid information on resident performance is critical to patient safety and training program improvement. The goals were to characterize important anesthesia resident performance gaps that are not typically evaluated, and to further validate scores from a multiscenario simulation-based assessment. Methods Seven high-fidelity scenarios reflecting core anesthesiology skills were administered to 51 first-year residents (CA-1s) and 16 third-year residents (CA-3s) from three residency programs. Twenty trained attending anesthesiologists rated resident performances using a seven-point behaviorally anchored rating scale for five domains: (1) formulate a clear plan, (2) modify the plan under changing conditions, (3) communicate effectively, (4) identify performance improvement opportunities, and (5) recognize limits. A second rater assessed 10% of encounters. Scores and variances for each domain, each scenario, and the total were compared. Low domain ratings (1, 2) were examined in detail. Results Interrater agreement was 0.76; reliability of the seven-scenario assessment was r = 0.70. CA-3s had a significantly higher average total score (4.9 ± 1.1 vs. 4.6 ± 1.1, P = 0.01, effect size = 0.33). CA-3s significantly outscored CA-1s for five of seven scenarios and domains 1, 2, and 3. CA-1s had a significantly higher proportion of worrisome ratings than CA-3s (chi-square = 24.1, P < 0.01, effect size = 1.50). Ninety-eight percent of residents rated the simulations more educational than an average day in the operating room. Conclusions Sensitivity of the assessment to CA-1 versus CA-3 performance differences for most scenarios and domains supports validity. No differences, by experience level, were detected for two domains associated with reflective practice. Smaller score variances for CA-3s likely reflect a training effect; however, worrisome performance scores for both CA-1s and CA-3s suggest room for improvement.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference47 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3