Multimodal Deep Learning Classifier for Primary Open Angle Glaucoma Diagnosis Using Wide-Field Optic Nerve Head Cube Scans in Eyes With and Without High Myopia

Author:

Bowd Christopher1,Belghith Akram1,Rezapour Jasmin12,Christopher Mark1,Jonas Jost B.3,Hyman Leslie4,Fazio Massimo A.5,Weinreb Robert N.1,Zangwill Linda M.1

Affiliation:

1. Viterbi Family Department of Ophthalmology, Shiley Eye Institute, Hamilton Glaucoma Center

2. Department of Ophthalmology, University Medical Center of the Johannes Gutenberg University Mainz

3. Department of Ophthalmology, Heidelberg University, Mannheim, Germany

4. Vickie and Jack Farber Vision Research Center, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA

5. Department of Ophthalmology and Visual Sciences, The University of Alabama at Birmingham, Birmingham, AL

Abstract

Précis: An optical coherence tomography (OCT)-based multimodal deep learning (DL) classification model, including texture information, is introduced that outperforms single-modal models and multimodal models without texture information for glaucoma diagnosis in eyes with and without high myopia. Background/Aims: To evaluate the diagnostic accuracy of a multimodal DL classifier using wide OCT optic nerve head cube scans in eyes with and without axial high myopia. Materials and Methods: Three hundred seventy-one primary open angle glaucoma (POAG) eyes and 86 healthy eyes, all without axial high myopia [axial length (AL) ≤ 26 mm] and 92 POAG eyes and 44 healthy eyes, all with axial high myopia (AL > 26 mm) were included. The multimodal DL classifier combined features of 3 individual VGG-16 models: (1) texture-based en face image, (2) retinal nerve fiber layer (RNFL) thickness map image, and (3) confocal scanning laser ophthalmoscope (cSLO) image. Age, AL, and disc area adjusted area under the receiver operating curves were used to compare model accuracy. Results: Adjusted area under the receiver operating curve for the multimodal DL model was 0.91 (95% CI = 0.87, 0.95). This value was significantly higher than the values of individual models [0.83 (0.79, 0.86) for texture-based en face image; 0.84 (0.81, 0.87) for RNFL thickness map; and 0.68 (0.61, 0.74) for cSLO image; all P ≤ 0.05]. Using only highly myopic eyes, the multimodal DL model showed significantly higher diagnostic accuracy [0.89 (0.86, 0.92)] compared with texture en face image [0.83 (0.78, 0.85)], RNFL [0.85 (0.81, 0.86)] and cSLO image models [0.69 (0.63, 0.76)] (all P ≤ 0.05). Conclusions: Combining OCT-based RNFL thickness maps with texture-based en face images showed a better ability to discriminate between healthy and POAG than thickness maps alone, particularly in high axial myopic eyes.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3