Affiliation:
1. Ophthalmology, Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Pisa
2. Ophthalmology, Department of Medicine and Aging Science, University G. D’Annunzio, Chieti-Pescara, Italy
Abstract
Précis:
Ultrasound cyclo plasty (UCP) using high-intensity focused ultrasound is an effective and safe procedure in lowering intraocular pressure (IOP) in patients with glaucoma, even in those with high myopia.
Purpose:
This study aimed to evaluate the efficacy and safety of UCP in glaucoma patients with high myopia.
Materials and Methods:
In this retrospective, single-center study, we enrolled 36 eyes divided into 2 groups based on axial length: group A (≥26.00 mm) and group B (<26.00 mm). We collected data about visual acuity, Goldmann applanation tonometry, biomicroscopy, and visual field before the procedure and at 1, 7, 30, 60, 90, 180, and 365 days after the procedure.
Results:
Mean IOP significantly decreased in both groups after treatment (P<0.001). Mean IOP reduction from baseline to the last visit was 9.8±6.6 mmHg (38.7%) in group A and 9.6±6.3 mmHg (34.8%) in group B (P<0.001). Mean IOP at the last visit was 15.8±4.1 mmHg in the myopic group and 18.1±5.6 mmHg in the non-myopic one. Regarding the number of IOP-lowering eyedrops being taken by our patients, statistically significant differences were found between groups A and B neither at baseline (2.8±0.9 and 2.6±1.0; P=0.568) nor 1 year after the procedure (2.5±1.1 and 2.6±1.1; P=0.762). No major complications occurred. All minor adverse events resolved within a few days.
Conclusion:
UCP seems to be an effective and well-tolerated strategy to lower IOP in glaucoma patients with high myopia.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献