Respiratory Variation of Internal Carotid Artery Blood Flow Peak Velocity Measured by Transfontanelle Ultrasound to Predict Fluid Responsiveness in Infants

Author:

Kim Eun-Hee1,Lee Ji-Hyun1,Song In-Kyung1,Kim Hee-Soo1,Jang Young-Eun1,Kim Jin-Tae1

Affiliation:

1. From the Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Jongno-gu, Seoul, Republic of Korea (E-H-.K., J-H.L., H-S.K., Y-E.J., J-T.K.); and the Department of Anesthesiology and Pain Medicine, Asan Medical Center, Ulsan College of Medicine, Songpa-gu, Seoul, Republic of Korea (I.-K.S.).

Abstract

Abstract Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New Background Cranial sonography is a widely used point-of-care modality in infants. The authors evaluated that the respiratory variation of the internal carotid artery blood flow peak velocity as measured using transfontanelle ultrasound can predict fluid responsiveness in infants. Methods This prospective observational study included 30 infants undergoing cardiac surgery. Following closure of the sternum, before and after the administration of 10ml · kg–1 crystalloid, the respiratory variation of the aorta blood flow peak velocity, pulse pressure variation, and central venous pressure were obtained. The respiratory variation of the internal carotid artery blood flow peak velocity was measured using transfontanelle ultrasound. Response to fluid administration was defined as an increase in stroke volume index, as measured with transesophageal echocardiography, greater than 15% of baseline. Results Seventeen subjects (57%) were responders to volume expansion. Before fluid loading, the respiratory variation of the internal carotid artery and the aorta blood flow peak velocity (means ± SD) of the responders were 12.6 ± 3.3% and 16.0 ± 3.8%, and those of the nonresponders were 8.2 ± 3.2% and 10.9 ± 3.5%, respectively. Receiver operating characteristic curve analysis showed that the respiratory variation of the internal carotid artery and the aorta blood flow peak velocity could predict fluid responsiveness; the area under the curve was 0.828 (P < 0.0001; 95% CI, 0.647 to 0.940) and 0.86 (P = 0.0001; 95% CI, 0.684 to 0.959), respectively. The cutoff values of the respiratory variation of the internal carotid artery and the aorta blood flow peak velocity were 7.8% (sensitivity, 94%; specificity, 69%) and 13% (sensitivity, 77%; specificity, 92%), respectively. Conclusions The respiratory variation of the internal carotid artery blood flow peak velocity as measured using transfontanelle ultrasound predicted an increase in stroke volume in response to fluid. Further research is required to establish any wider generalizability of the results.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3