Aortic Peak Flow Velocity As a Predictor of Fluid Responsiveness in Mechanically Ventilated Children: A Systematic Review and Meta-Analysis

Author:

Sethasathien Saviga1,Jariyasakoolroj Theerapon2,Silvilairat Suchaya1,Srisurapanont Manit3

Affiliation:

1. Division of Pediatric Cardiology, Department of Pediatrics, Faculty of Medicine Chiang Mai University, Chiang Mai, Thailand.

2. Division of Pediatric Critical Care Medicine, Department of Pediatrics, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.

3. Department of Psychiatry, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.

Abstract

Objectives: This meta-analysis aimed to determine the accuracy of the respiratory variations in aortic peak flow velocity (delta Vpeak) in predicting fluid responsiveness and the moderators of that accuracy. Data Sources: We performed searches for studies that used delta Vpeak as a predictor of fluid responsiveness in mechanically ventilated children in PubMed, Embase, Scopus, and CINAHL from inception to June 20, 2022. Study Selection and Data Extraction: Fifteen studies (n = 452) were included in this meta-analysis. The diagnostic test data of the included studies were synthesized as pooled sensitivity, specificity, and diagnostic odds ratio (DOR) and the area under the curve (AUC) of the summary receiver operating characteristic of delta Vpeak. Data Synthesis: The delta Vpeak cutoff values applied in these studies had a median of 12.3% (interquartile range, 11.50–13.25%). The pooled sensitivity and specificity of delta Vpeak were 0.80 (95% CI, 0.71–0.87) and 0.82 (95% CI, 0.75–0.87), respectively. The DOR of delta Vpeak was 23.41 (95% CI, 11.61–47.20). The AUC of delta Vpeak was 0.87. Subgroup analyses revealed that the accuracy of delta Vpeak was not moderated by ventilator settings, measures of delta Vpeak, gold standard index, the cutoff gold standard value of responders, type and volume of fluid, duration of fluid challenge, use of vasoactive drugs, general anesthesia, and cardiopulmonary bypass. Conclusions: By using the cutoff of approximately 12.3%, the delta Vpeak appears to have good accuracy in predicting fluid responsiveness in mechanically ventilated children. The moderators of delta Vpeak predictability are not found.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Critical Care and Intensive Care Medicine,Pediatrics, Perinatology and Child Health

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3