Abstract

Background: 3D scanning of the foot and ankle is gaining popularity as an alternative method to traditional plaster casting to fabricate ankle-foot orthoses (AFOs). However, comparisons between different types of 3D scanners are limited. Objective(s): The aim of this study was to evaluate the accuracy and speed of seven 3D scanners to capture foot, ankle, and lower leg morphology to fabricate AFOs. Study Design: Repeated-measures design. Methods: The lower leg region of 10 healthy participants (mean age 27.8 years, standard deviation [SD] 9.3) was assessed with 7 different 3D scanners: Artec Eva (Eva), Structure Sensor (SS I), Structure Sensor Mark II (SS II), Sense 3D Scanner (Sense), Vorum Spectra (Spectra), Trnio 3D Scanner App on iPhone 11 (Trnio 11), and Trnio 3D Scanner App on iPhone 12 (Trnio 12). The reliability of the measurement protocol was confirmed initially. The accuracy was calculated by comparing the digital scan with clinical measures. A percentage difference of #5% was considered acceptable. Bland and Altman plots were used to show the mean bias and limit of agreement (LoA) for each 3D scanner. Speed was the time needed for 1 complete scan. Results: The mean accuracy ranged from 6.4% (SD 10.0) to 230.8% (SD 8.4), with the SS I (21.1%, SD 6.8), SS II (21.7%, SD 7.5), and Eva (2.5%, SD 4.5) within an acceptable range. Similarly, Bland and Altman plots for Eva, SS I, and SS II showed the smallest mean bias and LoA 21.7 mm (LoA 25.8 to 9.3), 21.0 mm (LoA 210.3 to 8.3), and 0.7 mm (LoA 213 to 11.5), respectively. The mean speed of the 3D scanners ranged from 20.8 seconds (SD 8.1, SS I) to 329.6 seconds (SD 200.2, Spectra). Conclusions: Eva, SS I, and SS II appear to be the most accurate and fastest 3D scanners for capturing foot, ankle, and lower leg morphology, which could be used for AFO fabrication.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Rehabilitation,Health Professions (miscellaneous)

Reference22 articles.

1. Additive manufacturing of custom orthoses and prostheses—a review;Chen;Addit Manuf,2016

2. 3D Digitalization of the human body for use in orthotics and prosthetics;Koutny;Int J Medical Medicine Health Sci,2012

3. A review of the application of additive manufacturing in prosthetic and orthotic clinics from a biomechanical perspective;Wang;Engineering,2020

4. A comparison of four methods of obtaining a negative impression of the foot;Laughton;J Am Podiatr Med Assoc,2002

5. Digital healthcare technologies: modern tools to transform prosthetic care;Cabrera;Expet Rev Med Dev,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3