A Novel Method to Determine the Maximum Output of Individual Patients for an Active Transcutaneous Bone Conduction Implant Using Clinical Routine Data

Author:

Ghoncheh Mohammad1,Busch Susan12,Lenarz Thomas12,Maier Hannes12

Affiliation:

1. Department of Otolaryngology and Institute of Audioneurotechnology (VIANNA), Hannover Medical School, Hannover, Germany

2. Cluster of Excellence “Hearing4all”, Hannover Medical School, Hannover, Germany.

Abstract

Objectives: The maximum output provided by a bone conduction (BC) device is one of the main factors that determines the success when treating patients with conductive or mixed hearing loss. Different approaches such as sound pressure measurements using a probe microphone in the external auditory canal or a surface microphone on the forehead have been previously introduced to determine the maximum output of active transcutaneous BC devices that are not directly accessible after implantation. Here, we introduce a method to determine the maximum output hearing level (MOHL) of a transcutaneous active BC device using patients’ audiometric data. Design: We determined the maximum output in terms of hearing level MOHL (dB HL) of the Bonebridge using the audiometric and direct BC threshold of the patient together with corresponding force levels at hearing threshold and the maximum force output of the device. Seventy-one patients implanted with the Bonebridge between 2011 and 2020 (average age 45 ± 19 years ranging from 5 to 84 years) were included in this study. The analyses of MOHLs were performed by (1) dividing patients into two groups with better or worse average audiometric BC threshold (0.5, 1, 2, 4 kHz), on the ipsilateral side or (2) by separating the MOHLs based on better or worse frequency-by-frequency specific audiometric BC thresholds on the ipsilateral (implanted) side. Results: When using a frequency-by-frequency analysis obtained average ipsilateral MOHLs were in the range between 51 and 73 dB HL for frequencies from 0.5 to 6 kHz in the group with better audiometric BC threshold on the ipsilateral ears. The average contralateral MOHLs in the group with better contralateral hearing were in the range from 43 to 67 dB HL. The variability of the data was approximately 6 to 11 dB (SDs) across measured frequencies (0.5 to 6 kHz). The average MOHLs were 4 to 8 dB higher across frequencies in the group with better audiometric BC threshold on the ipsilateral ears than in the group with better audiometric BC threshold on the contralateral ears. The differences between groups were significant across measured frequencies (t test; p < 0.05). Conclusions: Our proposed method demonstrates that the individual frequency-specific MOHL on the ipsilateral and contralateral side of individual patients with a transcutaneous BC device can be determined mainly using direct and audiometric BC threshold data of the patients from clinical routine. The average MOHL of the implant was found 4 to 8 dB higher on the ipsilateral (implanted) side than on the contralateral side.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Speech and Hearing,Otorhinolaryngology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3