A Comparison of Tracheal Tube Tip Designs on the Passage of an Endotracheal Tube during Oral Fiberoptic Intubation

Author:

Ruari Greer J.1,Smith Sharon P.1,Strang Tim2

Affiliation:

1. Specialist Registrar in Anaesthetics.

2. Consultant Anaesthetist.

Abstract

Background The design of an endotracheal tube has been shown to influence the passage of the tube through the glottis during fiberoptic intubation. Difficulty in passing the endotracheal tube can occur if the aryepiglottic folds obstruct the passage of the bevel. The relevant aspects of endotracheal tube design include the shape of the bevel, the material used by the manufacturer, and the ability of the tube to conform to the shape of the fiberscope. The aim of the current study was to compare the ease of passage through the glottis of two different tubes. One tube was a wire reinforced polyvinyl chloride tube with a standard bevel and the other was a newly designed tube with a bevel of different shape and made of silicone rubber. The new design is for use with the a commerical intubating laryngeal mask. Methods The authors studied a population of 30 patients who received a standard anesthetic. In all cases, oral fiberoptic intubation was attempted. Anesthetic was administered to each patient using both tubes, and before the study the order of the tubes was randomized. The difficulty in passing the tube was assessed by a blinded observer and graded using a three-point scale (grade 1: no difficulty passing the tube; grade 2: obstruction to passing the tube relieved by withdrawal and a 90 degrees anticlockwise rotation; grade 3: obstruction necessitating more than one manipulation or external laryngeal manipulation). Results In 27 patients, no difficulty was shown by use of the silicone-tipped tube. In only three patients was there difficulty that necessitated a 90 degrees anticlockwise twist. With the wire-reinforced tube, no difficulty was experienced on 14 occasions. Grade 1 difficulty was experienced eight times and difficulty necessitating more than one maneuver, head movement, or external laryngeal manipulation was seen on eight occasions. Statistical significance was achieved at P = 0.0002 (Wilcoxon signed rank test). Conclusions The authors conclude that the use of the silicone-tipped tube with the new bevel design may provide an advantage in the clinical situation of fiberoptic intubation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference12 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3