The difference in rotation angle of the distal endotracheal tube through nasal approach

Author:

Tsukamoto Masanori,Goto Maho,Hitosugi Takashi,Yokoyama Takeshi

Abstract

Abstract Background Nasal intubation using a fiberoptic scope is a useful technique. In clinical practice, we have experienced difficulty in advancing the endotracheal tube (ETT) over the fiberoptic scope because of resistance to the passage of the ETT against rotation in the nasal cavity, when it gets hung up on structures of the laryngeal inlet. Several maneuvers have been proposed to overcome this difficulty. The gap between the tip of the ETT and the fiberoptic scope can be reduced using a thicker fiberoptic scope and a thinner ETT. Moreover, simultaneous rotation of the fiberoptic scope and ETT could lead to successful intubation by reducing impingement on the ETT. However, the discrepancy between these rotation angles is unclear. This observational prospective study aimed to investigate the discrepancy in the rotation angle between the ETT and fiberoptic scope during nasal intubation. Methods The patients (aged 20–80 years) who underwent nasal intubation for oral and maxillofacial surgery participated in three sizes of preformed nasal ETT and were intubated using a fiberoptic scope. They were divided into three groups; the ETT internal diameter (ID) 6.5 mm (6.5 group), ID 7.0 mm (7.0 group), and ID 7.5 mm (7.5 group). The ETT was then inserted through the nasal cavity into the pharynx. After the fiberoptic scope was advanced through the ETT above the glottis, simultaneous rotation by both the proximal end of the fiberoptic scope and ETT was performed in 90° and 180° in both right (clockwise) and left (counterclockwise) directions, and the rotation angle at the distal end of the ETT was monitored using a video laryngoscope (Pentax-AWS). Results A total of 39 patients were included in the study. When both the proximal end of the fiberscope and ETT were simultaneously rotated by 90°, in the 6.5 group (n = 13), the distal end of the ETT rotated by 47.8 ± 1.5°. In the 7.0 °group (n = 13), the distal end of the ETT rotated by 45.5 ± 1.0°. In the 7.5 group (n = 13), the distal end of the ETT rotated by 39.9 ± 1.0°. When the proximal end of the fiberscope and ETT were rotated by 180°, in the 6.5 group, the distal end of the ETT rotated by 166.2 ± 2.5°. In the 7.0 group, the distal end of the ETT rotated by 145.7 ± 2.2°. In the 7.5 group, the distal end of the ETT rotated by 115.1 ± 2.0°. All rotation angles in the distal end of the ETT were significantly lower than those in both the proximal end of the fiberscope and ETT (p < 0.05). Rotating right by 180° was significantly different among the three groups (p < 0.05), although rotating right by 90° was not significantly different. Similar results were obtained for the left rotation. Conclusion Simultaneous rotation by the proximal end of the ETT and fiberscope above the glottis for the nasal approach induced significant differences in the distal end of the ETT. The larger tube lagged by the resistance of the nasal passages during rotation. Therefore, the ETT does not rotate as much as the rotation angle. Trial registration This prospective observational study was conducted after receiving approval from the Ethics Review Board of Kyushu University Hospital (Approval No. 30–447).

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3