Effects of the Anesthetic Gases Xenon, Halothane, and Isoflurane on Calcium and Potassium Currents in Human Atrial Cardiomyocytes

Author:

Hüneke Rocco1,Jüngling Eberhard2,Skasa Marius3,Rossaint Rolf4,Lückhoff Andreas5

Affiliation:

1. Resident.

2. Chief Engineer.

3. Resident, Department of Cardiology.

4. Professor and Chairman, Department of Anesthesiology.

5. Professor, Department of Physiology.

Abstract

Background Negative inotropic and proarrhythmic side effects on the heart are well known for the volatile anesthetics halothane and isoflurane but not for the noble gas xenon. We investigated the effects of halothane, isoflurane, and xenon on calcium and potassium currents in human atrial myocytes to elucidate the cellular and molecular basis of their cardiac actions. Methods Atrial myocytes were prepared from the right auricles obtained from patients undergoing heart surgery. Ion currents were measured with the whole cell patch clamp technique during superfusion of the cells with solutions that contained halothane, isoflurane, or xenon at concentrations corresponding to their respective minimum alveolar concentration (MAC); gas concentrations were determined with the head space-gas chromatography/mass spectrometry/selected ion monitoring method. Results L-type calcium currents were significantly depressed by 31.9 +/- 4.1%, from -1.8 +/- 0.3 to -1.2 +/- 0.4 picoampere (pA)/picofarad (pF) (n = 4; P < 0.05) at 1 MAC halothane and by 21.7 +/- 9.2%, from -1.6 +/- 0.7 to -1.2 +/- 0.6 pA/pF (n = 7; P < 0.05) at 1 MAC isoflurane, but not affected by 70% xenon (1 MAC). Inwardly rectifying potassium currents were not influenced by any anesthetic. Halothane (1 MAC) significantly inhibited the transient as well as the sustained part of voltage-gated potassium outward currents, by 19.4 +/- 6.7%, from 6.7 +/- 2.1 to 5.4 +/- 1.6 pA/pF (n = 8; P < 0.05), and by 8.6 +/- 4.8%, from 5.5 +/- 1.7 to 5.0 +/- 1.5 pA/pF (n = 8; P < 0.05), respectively. Transient K+ outward currents were even more inhibited, by 25.8 +/- 4.8%, from 9.8 +/- 3.1 to 7.3 +/- 2.1 pA/pF (n = 5; P < 0.05) at 1 MAC isoflurane, whereas xenon evoked only a slight (albeit significant) inhibition, by 6.1 +/- 3.7%, from 8.2 +/- 6.0 to 7.7 +/- 5.8 pA/pF (n = 10; P < 0.05). Isoflurane and xenon did not affect sustained potassium currents. All effects of the anesthetics were fully reversible after washout. Conclusions Halothane and isoflurane exhibited considerable inhibitory effects on voltage-gated cardiac Ca2+ and K+ currents important for the duration of action potentials and the repolarization. Xenon, in contrast, did not affect Ca2+ currents and only slightly inhibited transient K+ outward currents, in line with the almost absent cardiac side effects of the noble gas.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference46 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3