Implant- and anesthesia-related factors affecting cardiopulmonary threshold intensities for vagus nerve stimulation

Author:

Ahmed UmairORCID,Chang Yao-ChuanORCID,Lopez Maria F,Wong Jason,Datta-Chaudhuri TimirORCID,Rieth LorenORCID,Al-Abed Yousef,Zanos StavrosORCID

Abstract

Abstract Objective. Vagus nerve stimulation (VNS) is typically delivered at increasing stimulus intensity until a neurological or physiological response is observed (‘threshold’) for dose calibration, preclinically and therapeutically. Factors affecting VNS thresholds have not been studied systematically. In a rodent model of VNS we measured neural and physiological responses to increasing VNS intensity, determined neurological and physiological thresholds and examined the effect of implant- and anesthesia-related factors on thresholds. Approach. In acute and chronic vagus implants (45 and 20 rats, respectively) VNS was delivered under isoflurane, ketamine-xylazine, or awake conditions. Evoked compound action potentials (CAPs) were recorded and activation of different fiber types was extracted. Elicited physiological responses were registered, including changes in heart rate (HR), breathing rate (BR), and blood pressure (BP). CAP and physiological thresholds were determined. Main results. The threshold for evoking discernable CAPs (>10 µV) (CAP threshold) is significantly lower than what elicits 5%–10% drop in heart rate (heart rate threshold, HRT) (25 µA ± 1.8 vs. 80 µA ± 5.1, respectively; mean ± SEM). Changes in BP and small changes in BR (bradypnea) occur at lowest intensities (70 µA ± 8.3), followed by HR changes (80 µA ± 5.1) and finally significant changes in BR (apnea) (310 μA ± 32.5). HRT and electrode impedance are correlated in chronic (Pearson correlation r= 0.47; p< 0.001) but not in acute implants (r = −0.34; p NS); HRT and impedance both increase with implant age (r= 0.44; p< 0.001 and r = 0.64; p < 0.001, respectively). HRT is lowest when animals are awake (200 µA ± 35.5), followed by ketamine-xylazine (640 µA ± 151.5), and isoflurane (1000 µA ± 139.5). The sequence of physiological responses with increasing VNS intensity is the same in anesthetized and awake animals. Pulsing frequency affects physiological responses but not CAPs. Significance. Implant age, electrode impedance, and type of anesthesia affect VNS thresholds and should be accounted for when calibrating stimulation dose.

Funder

United Therapeutics Corporation

Publisher

IOP Publishing

Subject

Cellular and Molecular Neuroscience,Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3