Bispectral Analysis of the Electroencephalogram Predicts Conscious Processing of Information during Propofol Sedation and Hypnosis

Author:

Kearse Lee A.,Rosow Carl,Zaslavsky Alan,Connors Patricia,Dershwitz Mark,Denman William

Abstract

Background The bispectral index (BIS) measures changes in the interfrequency coupling of the electroencephalogram (EEG). The purposes of this study were (1) to determine whether BIS correlates with responses to command during sedation and hypnosis induced by propofol or propofol and nitrous oxide, and (2) to compare BIS to targeted and measured concentrations of propofol in predicting participants' responses to commands. Methods Twenty volunteers (15 men and 5 women, aged 22-50 yr) were given propofol by computer-controlled infusion, and EEG was recorded for off-line analysis of BIS. Responses to randomly ordered verbal commands or voice plus touch were measured with two categorical scales (CS1 and CS2, respectively). All subjects received a propofol infusion targeted to achieve effect site concentrations of 1, 2, 4, 2, 1, and 0 microg/ml. Ten participants had repeated infusion, whereas 10 others breathed 30% nitrous oxide and oxygen and received a propofol infusion targeted for 0.5, 1, 2, 4, 2, 1, 0.5, and 0 microg/ml. Five minutes after each targeted concentration had been reached, CS1, CS2, and arterial propofol concentration were determined. The area under the receiver operating characteristic curve was used to compare the accuracy of (1) BIS, (2) targeted propofol concentration, (3) measured concentration, and (4) treatment history as predictors of response. Results Bispectral index was a strong predictor of CS1 and CS2 (P < 0.0001) and significantly more accurate than targeted or measured propofol concentrations (P < 0.0003 and P < 0.003, respectively). It also provided additional predictive power when combined with treatment history (P < 0.02). Nitrous oxide slightly decreased the probability of response at a given value of BIS (P < 0.05), but accuracy was unaffected. Conclusions Bispectral index accurately predicts response to verbal commands during sedation and hypnosis with propofol or propofol plus nitrous oxide. Accuracy is maintained in situations likely to be encountered during clinical use: when propofol concentrations are increasing or decreasing and when repeated measurements are made over time.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference36 articles.

Cited by 232 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3