Point-of-Care Tissue Oxygenation Assessment with SnapshotNIR for Alloplastic and Autologous Breast Reconstruction

Author:

Moritz William R.1,Daines John1,Christensen Joani M.1,Myckatyn Terence1,Sacks Justin M.1,Westman Amanda M.1

Affiliation:

1. From the Division of Plastic and Reconstructive Surgery, Department of Surgery, Washington University School of Medicine, St. Louis, Mo.

Abstract

Background: In breast reconstruction, mastectomy and free flaps are susceptible to vascular compromise and tissue necrosis. The SnapshotNIR device (Kent Imaging, Calgary, AB, Canada) utilizes near-infrared spectroscopy to measure tissue oxygen saturation (StO2) and hemoglobin concentration. Here, we report on the use of this device for StO2 monitoring among patients receiving alloplastic or autologous breast reconstruction. Methods: Patients receiving immediate alloplastic reconstruction after mastectomy or autologous reconstruction were enrolled. Preoperative, intraoperative, and postoperative images were taken of the flaps. StO2 and hemoglobin were measured at the following locations: superior and inferior breast, free flap skin paddle (when applicable), and un-operated control skin. Linear mixed effects model for repeated measurements was used to model measurements to estimate the area effect difference across time, time effect difference across area, and pairwise comparisons between two areas at each time point. Results: Thirty-two breasts underwent alloplastic reconstruction; 38 breasts underwent autologous reconstruction. No enrollees developed skin necrosis. StO2 was highest after mastectomy and closure in alloplastic reconstructions. StO2 was observed to decline at follow-up in autologous reconstructions. Mean preoperative StO2 was highest in breasts that had previously undergone mastectomy and alloplastic reconstruction. Conclusions: The SnapshotNIR device detected normal spatial and temporal differences in tissue oxygenation over the operative course of alloplastic and autologous breast reconstruction. A multi-institutional, prospective clinical trial is needed to determine the sensitivity and specificity of this device for detecting skin flap necrosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Surgery,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3