Characteristics and factors associated with the position of the haptic after ICL V4C implantation

Author:

Tan Weina,Chen QianORCID,Yang Ruibo,Wang ZhengORCID,Zeng QingyanORCID,Lei Xiaohua,Jin Lina,Zhao ShaozhenORCID

Abstract

Purpose: To assess the position of implantable collamer lens (ICL) haptic after ICL V4C implantation using standardized panoramic ultrasound bimicroscopy (UBM), to analyze its characteristics, associated factors, and the relationship with the clinical vault quantitatively. Setting: Hankou Aier Eye Hospital, Wuhan, Hubei, China. Design: Cross-sectional study. Methods: 167 subjects (323 eyes) implanted with ICL V4C who had a 3-month follow-up with UBM examination were included in this study. The relative position of ICL to the adjacent structure and ICL haptic-related parameters (the final tip point of ICL haptic [ftICL haptic], measured from the scleral spur to the final tip of the ICL haptic, the posterior of the ICL to ICL haptic [ICL arc], measured from the posterior surface of the ICL to the ICL haptic plane, and the height of the crystalline lens from the ICL haptic (lens arc), measured from the anterior surface of the crystalline lens to the ICL haptic plane and other parameters), were estimated on the UBM image. Eyes were divided into 3 subgroups according to the ftICL haptic (Group 1: ≤0.5 mm; Group 2: 0.5 to 1.0 mm; and Group 3:≥1.0 mm, respectively), and the factors associated with the ICL haptic-related parameters and their impact on the clinical vault were evaluated. Results: The haptics could be imaged in the ciliary sulcus, on the ciliary body, and under the ciliary body in 629 (48.7%), 525 (40.6%), and 138 (10.7%) eyes, respectively. The ftICL haptic and the summation of ICL arc and lens arc showed a correlation with the clinical vault (r = −0.34, P = .00; r = 0.87, P = .00). When the ftICL haptic results were divided into 3 groups, the percentage of eyes that exhibited clinical vault >750 μm were lowest in Group 3. Multivariate regression analysis showed spherical equivalent, white-to-white (WTW), anterior chamber volume (ACV) and iris–ciliary angle (ICA); the difference between the implanted ICL size and horizontal sulcus-to-sulcus (ICL size-STS) were associated with the ftICL haptic. The IOP, WTW, ACV, and the ICL size-STS were significantly associated with ICL arc, while the ICA and lens rise were associated with lens arc. Conclusions: The position of ICL haptic was associated with the clinical vault. Its quantitative evaluation may provide valuable information to help clinicians to select the best ICL size before surgery and understand the formation of clinical vault after surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3