What Are the Relative Associations of Surgeon Performance and Prosthesis Quality With THA Revision Rates?

Author:

Hoskins Wayne12ORCID,Bingham Roger3ORCID,Graves Stephen E.4,Harries Dylan4,Cuthbert Alana R.5,Corfield Sophia4,Smith Paul4,Vince Kelly G.2

Affiliation:

1. Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, Australia

2. Department of Orthopaedics, Northland District Health Board, Whangarei, New Zealand

3. Traumaplasty Melbourne, East Melbourne, Australia

4. Australian Orthopaedic Association National Joint Replacement Registry, Adelaide, Australia

5. South Australian Health and Medical Research Institute (SAHMRI), Adelaide, Australia

Abstract

Background Many factors, including some related to the patient, implant selection, and the surgeon’s skill and expertise, likely contribute to the risk of THA revision. However, surgeon factors have not been extensively analyzed in national joint replacement registries, and there is limited insight into their potential as a confounding variable for revision outcomes; for example, if surgeons with higher revision rates choose more successful prostheses, would this alone reduce their revision rate? Questions/purposes This study used Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) data for patients receiving primary THA for a diagnosis of osteoarthritis to answer the following questions: (1) Will the difference in revision rates among surgeons change or disappear when only procedures performed with the best prostheses or prostheses that have been identified as having higher revision rates are considered? (2) Is the benefit associated with using the best-performing prostheses different among surgeons with different revision rates? (3) Do the reasons for revision differ between surgeons with higher rates of revision compared with surgeons with lower rates of revision? Methods All primary THA procedures performed and recorded in the AOANJRR for osteoarthritis from September 1, 1999, to December 31, 2022, were considered for inclusion. Each THA prosthesis used was categorized per the AOANJRR as superior-performing, middle-performing, or identified as having a higher rate of revision by the AOANJRR benchmarking process. Surgeons who had performed at least 50 procedures and had a recorded 2-year cumulative percent revision (CPR) were included. After applying these restrictions, the study consisted of 302,066 procedures performed by 476 known surgeons. For the primary outcome measure of all-cause revision, we examined the variation in all-cause revision rates across individual surgeons when different classes of devices were used to assess whether differences between surgeons persisted when accounting for prosthesis selection. For the purposes of descriptively comparing reasons for revision between surgeons with higher-than-average or lower-than-average risk of revision, surgeons were classified into quartiles and outcomes compared when these surgeons used the same class of prosthesis. Results The difference in rates of revision among surgeons remained even after accounting for the effects of the prosthesis used. For any given surgeon, identified prostheses were associated with higher revision rates compared with both superior-performing prostheses (HR 1.73 [95% CI 1.57 to 1.92]; p < 0.01) and medium-performing prostheses (HR 1.31 [95% CI 1.20 to 1.43]; p < 0.01). All surgeons demonstrated a lower revision rate when using a superior-performing prosthesis, but the difference was greatest for surgeons with the highest rates of revision. Surgeons with the lowest rates of revision had a 19-year CPR of 3.9% (95% CI 3.0% to 5.0%) when using a superior-performing prosthesis compared with 5.4% (95% CI 4.0% to 7.3%) for procedures in which an identified prosthesis was used. Surgeons with the highest rates of revision had a 19-year CPR of 10.9% (95% CI 8.6% to 13.8%) when using a superior-performing prosthesis, and this increased to 20.4% (95% CI 18.0% to 23.1%) for procedures in which an identified prosthesis was used. The reasons for revision differ between surgeons, with causes of revision likely preventable and not related to the prosthesis choice being apparent for surgeons with high revision rates. Conclusion The choice of implant and the surgeon performing the index procedure both affected the risk of revision as well as the reasons for revision. Surgeons could improve the survivorship of the arthroplasties they perform by choosing implants identified by registries as having lower revision rates. Acceptance of the fact that surgeons have different revision rates is needed, and detailed analysis is required to explain why surgeons with high revision rates have increased rates of likely preventable revisions, and outside of prosthesis choice, how revision rates can be lowered. The influence of training, fellowship completion, ongoing education, patient selection, indications for surgery, and factors underlying prosthesis decision-making should be assessed. The surgeon performing THA is an important confounder that should be considered in future registry analyses. Level of Evidence Level III, therapeutic study.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3