Approaches to minimising the epidemiological impact of sources of systematic and random variation that may affect biochemistry assay data in UK Biobank

Author:

Allen Naomi E.ORCID,Arnold Matthew,Parish Sarah,Hill Michael,Sheard SimonORCID,Callen Howard,Fry Daniel,Moffat Stewart,Gordon Mark,Welsh SamanthaORCID,Elliott PaulORCID,Collins Rory

Abstract

Background: UK Biobank is a large prospective study that recruited 500,000 participants aged 40 to 69 years, between 2006-2010.The study has collected (and continues to collect) extensive phenotypic and genomic data about its participants. In order to enhance further the value of the UK Biobank resource, a wide range of biochemistry markers were measured in all participants with an available biological sample. Here, we describe the approaches UK Biobank has taken to minimise error related to sample collection, processing, retrieval and assay measurement. Methods: During routine quality control checks, the laboratory team observed that some assay results were lower than expected for samples acquired during certain time periods. Analyses were undertaken to identify and correct for the unexpected dilution identified during sample processing, and for expected error caused by laboratory drift of assay results. Results: The vast majority (92%) of biochemistry serum assay results were assessed to be not materially affected by dilution, with an estimated difference in concentration of less than 1% (i.e. either lower or higher) than that expected if the sample were unaffected; 8.3% were estimated to be diluted by up to 10%; very few samples appeared to be diluted more than this. Biomarkers measured in urine (creatinine, microalbumin, sodium, potassium) and red blood cells (HbA1c) were not affected. In order to correct for laboratory variation over the assay period, all assay results were adjusted for date of assay, with the exception of those that had a high biological coefficient of variation or evident seasonal variability: vitamin D, lipoprotein (a), gamma glutamyltransferase, C-reactive protein and rheumatoid factor. Conclusions: Rigorous approaches related to sample collection, processing, retrieval, assay measurement and data analysis have been taken to mitigate the impact of both systematic and random variation in epidemiological analyses that use the biochemistry assay data in UK Biobank.

Funder

Medical Research Council

Diabetes UK

British Heart Foundation

Wellcome Trust

Publisher

F1000 Research Ltd

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3