Paraprotein interferences: Insights from a short study involving multiple platforms and multiple measurands.

Author:

Sarkar Rajarshi1

Affiliation:

1. Drs. Tribedi & Roy Diagnostic Laboratory

Abstract

Abstract Background: Though paraproteinaemic interferences is a well-known phenomenon in clinical chemistry, a large-scale evaluation study involving multiple paraproteinaemic specimens on multiple platforms including multiple measurands with an aim to provide a predictive analysis, is singularly lacking. The present study aims to fill this gap in research. Material & Methods: This cross-sectional non-interventional observational study involved thirteen paraproteinaemic subjects, determined their gamma globulin characterization and measured their total bilirubin, direct bilirubin, HDL-cholesterol, calcium, inorganic phosphate, iron and unsaturated iron binding capacity (UIBC) levels on a dry chemistry platform (Vitros 350) as the established method and two wet chemistry platforms (AU5800 and Cobas 6000) as the evaluation methods. Data thus generated was analyzed for any significant variation and tested if such variation increased with decreasing albumin/ globulin ratio. Results: Significant variation between dry chemistry and wet chemistry measurements were obtained for direct bilirubin, HDL and iron on AU5800 with p-values of 0.0009, <0.0001 and 0.0466 respectively. Similarly, discrepant results were obtained on Cobas 6000 for direct bilirubin and iron, with p-values of <0.0001 and 0.0002 respectively. Additionally, UIBC measurements on AU5800 varied significantly with increasing amounts of paraprotein present in the specimen (p-value = 0.0207). Conclusion: This study emphasizes on predictive analyses to show that paraprotein interferences are fairly common on wet chemistry platforms. Evolving algorithms for monitoring of reaction curves can minimize release of erroneous results due to such interferences.

Publisher

Research Square Platform LLC

Reference33 articles.

1. Drug interference in clinical chemistry: Recommendation of drugs and their concentrations to be used in drug interference studies;Sonntag Oswald;Annals of clinical biochemistry,2001

2. "Interferences in immunoassays: review and practical algorithm";Wauthier Loris;Clinical Chemistry and Laboratory Medicine (CCLM),2022

3. Prevalence of Monoclonal Gammopathy of Undetermined Significance: A Systematic Review;Wadhera RK;Mayo Clin Proc,2010

4. J Backus. Avoiding Incorrect Laboratory Assay Results Caused by Paraproteins. Produced by Ortho Clinical Diagnostics Scientific Affairs Department 2011.

5. Paraproteins are a common cause of interferences with automated chemistry methods;Yang Y;Arch Pathol Lab Med,2008