Textile wastewater treatment plant performance assessment using time-function based effluent quality index and multiple regression models

Author:

Wondim Tilik Tena1,Dzwairo Rimuka Bloodless2,Aklog Dagnachew1,Wakjira Eshetu Janka3,Samarakoon Gamunu3,Dereseh Mekuria Mulusew4

Affiliation:

1. Department of Water Supply and Sanitary Engineering, Bahir Dar Institute of Technology, Bahir Dar University, 26, Bahir Dar, Ethiopia

2. Department of Civil Engineering, Durban University of Technology, Midlands, PO Box 101112, 3209, Imbali, South Africa

3. Department of Process, Energy and Environmental Technology, University of South-Eastern Norway, 3918, Porsgrunn, Norway

4. Excellence Enterprise, Bahir Dar, Ethiopia

Abstract

Abstract Extensive water and chemicals are used in the textile industry processes. Therefore, treatment of textile wastewater is vital to protect the environment, maintain the public health, and recover resources. However, due to inadequate quality data, inexperienced plant operators, and inconsistent measurements, a real-time prediction of effluent quality of a textile wastewater treatment plant is difficult. Thus, the aim of this study was to characterize the wastewater physicochemical properties and evaluate the performance of the textile factory wastewater treatment plant (WWTP) in Bahir Dar, Ethiopia. Inlet and outlet of the WWTP, samples were collected for six months and analyzed on-site and in a laboratory for parameters including, dissolved oxygen, pH, temperature, total Kjeldhal nitrogen (TKN), chemical oxygen demand (COD), biochemical oxygen demand (BOD5), total suspended solids (TSS), total nitrogen (TN), total phosphorous (TP), nutrients, and metallic compounds. The TSS, BOD5, COD, TP, nitrite, ammonia, and total chromium result were above the discharge limit with 73.2 mg/L, 48.45 mg/L, 144.08 mg/L, 7.9 mg/L, 1.36 mg/L, 1.96 mg/L, and 0.16 mg/L, respectively. Multiple regression models were developed for each overall, net moving average and instantaneous effluent quality index (EQI). The predictor parameters BOD5, TN, COD, TSS, and TP (R2 = 0.995 to 1.000) estimated the net pollution load as 492.55 kg/d and 655.44 kg/d. Except TN, TKN, and NO3, the remaining six performance parameters were violating the permissible limit daily. Furthermore, the overall plant efficiency was predicted as 38 % and 42 % for the moving average and instantaneous EQI, respectively. Our study concluded that the integrated regression models and EQI can easily estimate the plant efficiency and daily possible pollution load.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3