Affiliation:
1. Repsol S.A., Engineering Department, Madrid, Spain
2. Faculty of Computer Science, Technical University of Madrid, Madrid, Spain
Abstract
This paper presents our modelling of a FCCU stripper, following our earlier
research. This model can measure stripper efficiency against the most
important variables: pressure, temperature, residence time and steam flow.
Few models in the literature model the stripper and usually they do against
only one variable. Nevertheless, there is general agreement on the
importance of the stripper in the overall process, and the fact that there
are few models maybe it is due to the difficulty to obtain a comprehensive
model. On the other hand, the proposed model does use all the variables of
the stripper, calculating efficiency on the basis of steam flow, pressure,
residence time and temperature. The correctness of the model is then
analysed, and we examine several possible scenarios, like decreasing the
steam flow, which is achieved by increasing the temperature in the stripper.
Publisher
National Library of Serbia
Subject
General Chemical Engineering
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献