Effect of Finishing and Polishing on Roughness and Gloss of Lithium Disilicate and Lithium Silicate Zirconia Reinforced Glass Ceramic for CAD/CAM Systems

Author:

Vichi A1,Fonzar R Fabian2,Goracci C3,Carrabba M4,Ferrari M5

Affiliation:

1. Alessandro Vichi, DDS, PhD, Department of Medical Biotechnologies, University of Siena, Siena, Italy. Faculty of Medical Sciences, LUdeS HEI Foundation, Lugano, Switzerland – La Valletta, Malta

2. Riccardo Fabian Fonzar, DDS, PhD, Department of Medical Biotechnologies, University of Siena, Siena, Italy

3. Cecilia Goracci, DDS, PhD, Department of Medical Biotechnologies, University of Siena, Siena, Italy

4. Michele Carrabba, DDS, PhD, Department of Medical Biotechnologies, University of Siena, Siena, Italy

5. Marco Ferrari, MD, DMD, PhD, Department of Medical Biotechnologies, University of Siena, Siena, Italy and Department of Restorative Dentistry, University of Leeds, UK

Abstract

SUMMARY Objective: To assess the efficacy of dedicated finishing/polishing systems on roughness and gloss of VITA Suprinity and IPS e.max CAD. Method: A total of 24 blocks of Suprinity and 24 of e.max were cut into a wedge shape using an InLab MC-XL milling unit. After crystallization, the 24 Suprinity wedges were divided into four subgroups: group A.1: Suprinity Polishing Set Clinical used for 30 seconds and group A.2: for 60 seconds; group A.3: VITA Akzent Plus Paste; and group A.4: spray. The 24 e.max wedges (group B) were divided into four subgroups according to the finishing procedure: group B.1: Optrafine Ceramic Polishing System for 30 seconds and group B.2: for 60 seconds; group B.3: IPS e.max CAD Crystall/Glaze paste; and group B.4: spray. After finishing/polishing, gloss was assessed with a glossmeter and roughness evaluated with a profilometer. Results were analyzed by applying a two-way analysis of variance for gloss and another for roughness (α=0.05). One specimen per each subgroup was observed with a scanning electron microscope. Results: For roughness, materials and surface were significant factors (p<0.001). Suprinity exhibited significantly lower roughness than e.max. Also the Material-Surface Treatment interaction was statistically significant (p=0.026). For gloss, both material and surface treatment were significant factors (p<0.001). VITA Suprinity showed significantly higher gloss than e.max. Also the Material-Surface Treatment interaction was statistically significant (p<0.001). Conclusions: Manual finishing/polishing for 60 seconds and glazing paste are the most effective procedures in lowering the roughness of CAD/CAM silica-based glass ceramics. Manual finishing/polishing for 60 seconds allows milled silica-based glass ceramics to yield a higher gloss. VITA Suprinity displayed higher polishability than IPS e.max CAD.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3