Author:
Marcellin-Little D. J.,Lascelles B. D. X.,Roe S. C.
Abstract
SummaryA Helica short-stemmed femoral prosthesis that was identified as being loose one year after implantation was revised with a standard long stem cementless BFX femoral pros-thesis. A double pelvic osteotomy was also performed to improve the orientation of the stable acetabular cup. Despite complete resorption of the femoral neck, and a large perforation of the lateral femoral cortex, the revision stem did not subside or rotate. The prosthetic joint did not dislocate. At re-evaluation two years after revision surgery, the prosthetic components were stable. Signs of bone ingrowth into the stem and cup were evident on radiographs. The dog had a seven percent greater thigh muscle girth in the limb implanted with the hip prosthesis compared to the contralateral limb, and was very active with no lameness.
Subject
General Veterinary,Animal Science and Zoology
Cited by
6 articles.
订阅此论文施引文献